Hybrid Approach of Aortic Diseases: Zone 1 Delivery and Volumetric Analysis on the Descending Aorta
نویسندگان
چکیده
INTRODUCTION Conventional techniques of surgical correction of arch and descending aortic diseases remains as high-risk procedures. Endovascular treatments of abdominal and descending thoracic aorta have lower surgical risk. Evolution of both techniques - open debranching of the arch and endovascular approach of the descending aorta - may extend a less invasive endovascular treatment for a more extensive disease with necessity of proximal landing zone in the arch. OBJECTIVE To evaluate descending thoracic aortic remodeling by means of volumetric analysis after hybrid approach of aortic arch debranching and stenting the descending aorta. METHODS Retrospective review of seven consecutive patients treated between September 2014 and August 2016 for diseases of proximal descending aorta (aneurysms and dissections) by hybrid approach to deliver the endograft at zone 1. Computed tomography angiography were analyzed using a specific software to calculate descending thoracic aorta volumes pre- and postoperatively. RESULTS Follow-up was done in 100% of patients with a median time of 321 days (range, 41-625 days). No deaths or permanent neurological complications were observed. There were no endoleaks or stent migrations. Freedom from reintervention was 100% at 300 days and 66% at 600 days. Median volume reduction was of 45.5 cm3, representing a median volume shrinkage by 9.3%. CONCLUSION Hybrid approach of arch and descending thoracic aorta diseases is feasible and leads to a favorable aortic remodeling with significant volume reduction.
منابع مشابه
Updates in cardiovascular surgery - hybrid procedures in acute debakey type I aortic dissection.
Acute type A aortic dissection remains a great challenge for the cardiac surgeon, with alarmingly high mortality and morbidity rate. The ‘standardized’ surgical management for the Debakey I dissection used to be replacement of the ascending portion the aorta which leaves the patient with a residual ‘type III’ dissection beyond the aortic arch, that can cause disease progression, operative bleed...
متن کاملDescending endografts for type A dissections: con.
An important goal of surgical repair of type A aortic dissection is to resect the intimal tear. Studies on the fate of residual dissection after acute type A aortic dissection repair in the past decade have driven surgeons to seek procedures to avoid distal reoperation. Aggressive surgical approach with total arch replacement in acute type A dissection has demonstrated lower incidence of distal...
متن کاملOverall Essen's experience with the E-vita open hybrid stent graft system and evolution of the surgical technique.
BACKGROUND The hybrid stent graft prosthesis E-vita open was designed and introduced by us in 2005 to avoid a two-stage surgical approach in the surgical treatment of complex thoracic aortic disease. Experience in ascending aortic and arch replacement with simultaneous stent grafting of the descending aorta was accumulated over the past 8 years. Facilitation of surgical technique by moving the ...
متن کاملA Single-Stage Repair of Arch and Descending Thoracic Aortic Aneurysms Using Jotec E-vita Open Plus Hybrid Stent Graft Combined With Antegrade Deployment of Thoracic Endograft.
We report a unique case of a 63-year-old female with extensive peripheral vascular disease who underwent a single-stage surgical repair of the aortic arch and descending thoracic aortic aneurysm utilizing the Jotec E-vita Open Plus hybrid stent graft system combined with antegrade deployment of a thoracic endograft via a median sternotomy.
متن کاملDirect videoscopic approach to the descending thoracic aorta for aortic arch endograft delivery: evaluation in a porcine model.
PURPOSE To examine the feasibility of a direct videoscopic approach to the descending thoracic aorta for endograft delivery to the aortic arch. METHODS A double purse-string suture was placed on the aorta of 3 pigs via a thoracoscopic approach. Subsequently, the aorta was cannulated in the center of the purse-string. A 22-F delivery catheter was advanced under fluoroscopic control over a guid...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 32 شماره
صفحات -
تاریخ انتشار 2017