Sieve Electrodes for Neural Implants
نویسندگان
چکیده
An in vitro model was developed to characterise the electrical properties of silicon microfabricated recording electrodes, using a Cu-wire mimicing a neural signal source. Phosphorous doped electrodes were used to achieve an all silicon device. The model was used to study signal amplitude as a function of distance between the electrode surface and the signal source. Signal crosstalk to neighbouring electrodes on the chips were recorded.The crosstalk was found to be 6 dB using an external reference electrode. Improvements were accomplished with an on chip reference electrode giving an amplitude crosstalk suppression of 20 dB. It was found that the amplitude decreased by a factor of 2 at a distance of 50 pm between the electrode surface and the signal source. Sieve electrodes were also implanted in the rat sciatic nerve and following a 10 week nerve regeneration period the dorsal and ventral (L5) roots in the spinal cord were stimulated. Compound action potentials were recorded via the chip. Lower leg muscle contraction activity was also induced by stimulating the regenerated sciatic nerve via the sieve electrode.
منابع مشابه
Regenerated Sciatic Nerve Axons Stimulated through a Chronically Implanted Macro-Sieve Electrode
Sieve electrodes provide a chronic interface for stimulating peripheral nerve axons. Yet, successful utilization requires robust axonal regeneration through the implanted electrode. The present study determined the effect of large transit zones in enhancing axonal regeneration and revealed an intimate neural interface with an implanted sieve electrode. Fabrication of the polyimide sieve electro...
متن کاملInterfacing peripheral nerve with macro-sieve electrodes following spinal cord injury
Macro-sieve electrodes were implanted in the sciatic nerve of five adult male Lewis rats following spinal cord injury to assess the ability of the macro-sieve electrode to interface regenerated peripheral nerve fibers post-spinal cord injury. Each spinal cord injury was performed via right lateral hemisection of the cord at the T9-10 site. Five months post-implantation, the ability of the macro...
متن کاملChronic recording of regenerating VIIIth nerve axons with a sieve electrode.
A micromachined silicon substrate sieve electrode was implanted within transected toadfish (Opsanus tau) otolith nerves. High fidelity, single unit neural activity was recorded from seven alert and unrestrained fish 30 to 60 days after implantation. Fibrous coatings of genetically engineered bioactive protein polymers and nerve guide tubes increased the number of axons regenerating through the ...
متن کاملFunctional regeneration of glossopharyngeal nerve through micromachined sieve electrode arrays.
To assess the potential of micromachined silicon sieve electrodes for long term recordings from single afferent sensory fibers, we implanted them between the cut ends of rat glossopharyngeal nerves which innervate taste and somatosensory receptors on the posterior tongue. After the implants had been in place for an average of 101 days nerve regeneration was measured using histological and elect...
متن کاملBoron-Doped Nanocrystalline Diamond Electrodes for Neural Interfaces: In vivo Biocompatibility Evaluation
Boron-doped nanocrystalline diamond (BDD) electrodes have recently attracted attention as materials for neural electrodes due to their superior physical and electrochemical properties, however their biocompatibility remains largely unexplored. In this work, we aim to investigate the in vivo biocompatibility of BDD electrodes in relation to conventional titanium nitride (TiN) electrodes using a ...
متن کامل