The accuracy of rest and exercise radionuclide angiocardiography (RNA) and exercise treadmill testing (ETT) for diagnosis of three-vessel or left main coronary artery disease (extensive CAD) was determined in 544 patients. ETT and RNA sensitivities were similar (88% vs 92%, NS), but ETT was more specific than RNA (46% vs 34%, p less than 0.01). The prevalence of extensive CAD in patients with a positive treadmill (41%) increased only 3% when the RNA was also positive. However, in the 292 patients with a negative or indeterminate ETT, a positive RNA increased this prevalence from 16% to 23%, while a negative RNA decreased this prevalence to 5%. These results support the initial use of ETT followed by RNA if the treadmill is negative or indeterminate for diagnosis in a population with a high prevalence of extensive CAD. This approach separates patients into subgroups with a high or low probability of extensive CAD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coronary Artery Disease by Radionuclide Measurement of Left Ventricular Function During Rest and Exercise

Rest and exercise radionuclide angiocardiographic measurements of left ventricular function were obtained in 496 patients who underwent cardiac catheterization for chest pain. Two hundred forty-eight of these patients also had an exercise treadmill test. An ejection fraction less than 50% was the abnormality of resting left ventricular function that provided the greatest diagnostic information....

متن کامل

Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]

Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...

متن کامل

Left Ventricular Diastolic Performance

We used first-pass radionuclide angiocardiography to assess filling fraction during the first third of diastole, peak filling rate and peak filling rate during the first third of diastole as indexes of left ventricular diastolic performance at rest and after upright bicycle exercise in 32 normal patients and 68 patients with coronary artery disease. The mean filling fraction was unchanged from ...

متن کامل

Left ventricular diastolic performance at rest and during exercise in patients with coronary artery disease. Assessment with first-pass radionuclide angiography.

We used first-pass radionuclide angiocardiography to assess filling fraction during the first third of diastole, peak filling rate and peak filling rate during the first third of diastole as indexes of left ventricular diastolic performance at rest and after upright bicycle exercise in 32 normal patients and 68 patients with coronary artery disease. The mean filling fraction was unchanged from ...

متن کامل

Application of Anatomical and Functional Modalities in Detection of Silent Myocardial Ischemia in Asymptomatic Diabetic Patients- A Review Article

Cardiovascular disease (CAD) screening in asymptomatic patients with diabetes mellitus is controversial. An exercise stress test is a safe and effective initial testing for Ischemic Heart Disease (IHD) screening. Treadmill stress test is not the best screening method for a particular patient who is not able to exercise, abnormal electrocardiogram (ECG) or positive exercise treadmill test (ETT) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 67 6  شماره 

صفحات  -

تاریخ انتشار 1983