Direct semiquantitative screening of drugs of abuse in serum and whole blood by means of CEDIA DAU urine immunoassays.

نویسندگان

  • S Iwersen-Bergmann
  • A Schmoldt
چکیده

The purpose of this study was to test the direct applicability of CEDIA DAU urine immunoassays to serum or whole blood. The performance of the urine assays for sensitive screening of amphetamines (AMP), benzoylecgonine (BZE), benzodiazepines (BENZ), methadone (MET), opiates (OPI), and tetrahydrocannabinol carboxylic acid (THCCOOH) was evaluated on the BM/Hitachi 911 analyzer with unpretreated serum and whole blood. The limit of detection was 0 ng/mL for all tests. Cutoff values were set from 10 to 40 ng/mL for the different assays. The assays were found to be linear between the following concentrations: AMP 0-2500 ng/mL, BZE 0-1200 ng/mL, BENZ 0-1600 ng/mL, MET 0-600 ng/mL, OPI 0-720 ng/mL, and THCCOOH 24-60 ng/mL. Precision results (within run) for different concentrations were as follows: AMP 3.1-5.7%, BZE 2.4-6.6%, BENZ 4.3-8.0%, MET 2.0-5.5%, OPI 2.8-7.6%, and THCCOOH 1.4-2.4%. Between-run results were as follows: AMP 8.7-15.5%, BZE 6.4-7.5%, BENZ 8.2-15.8%, MET 2.7-5.1%, OPI 4.3-11.2%, and THCCOOH 2.6-7.4%. Sensitivity, specificity, and comparison of CEDIA semiquantitation with GC-MS quantitative results were performed on 500 original serum and whole blood samples. The data provided sufficient documentation to use the CEDIA urine-screening technique without any adaptation as a sensitive serum/whole blood screening for BZE, BENZ, MET, OPI, and THCCOOH. Serum screening for amphetamines is not sensitive enough in the unchanged urine mode. It will require some adaptation to a serum mode (probably a higher sample volume [BM/Hitachi 911] combined with protein precipitation of the sample).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cloned enzyme donor immunoassay (CEDIA) for drugs-of-abuse screening.

Large numbers of specimens (5000-18,000) were screened for amphetamines, barbiturates, cocaine, marijuana, opiates, and phencyclidine by RIA (Roche), Emit II (Syva), and a new immunoassay, CEDIA (cloned enzyme donor immunoassay, Microgenics). All immunoassays performed equivalently for cocaine, opiates, and phencyclidine. All immunoassays detected the same amphetamine/methamphetamine-positive s...

متن کامل

KIMS, CEDIA, and HS-CEDIA immunoassays are inadequately sensitive for detection of benzodiazepines in urine from patients treated for chronic pain.

BACKGROUND Patients treated for chronic pain may frequently undergo urine drug testing to monitor medication compliance and detect undisclosed prescribed or illicit drug use. Due to the increasing use and abuse of benzodiazepines, this class of medications is often included in drug screening panels. However, immunoassay-based methods lack the requisite sensitivity for detecting benzodiazepine u...

متن کامل

Determination of designer drug cross-reactivity on five commercial immunoassay screening kits.

The detection of new designer drugs is often a difficult issue in forensic urine drug testing as immunoassays are the primary screening methodology for drugs of abuse in many of these laboratories. Cross-reactivity of compounds with immunoassay kits can either aid or complicate the detection of a variety of drug and drug metabolites. For instance, emerging designer drugs that share structural s...

متن کامل

Cross-reactivity of the CEDIA buprenorphine assay in drugs-of-abuse screening: influence of dose and metabolites of opioids

PURPOSE The cloned enzyme donor immunoassay (CEDIA) for buprenorphine is applied for both urine drugs-of-abuse screening and compliance monitoring. Sensitivity, specificity, and optimal cutoff of this assay have differed between studies. This may indicate that cross-reactivity has to be taken into account during assay evaluation. We therefore investigated the performance of the CEDIA buprenorph...

متن کامل

Interactions among enzyme, antibody, drug, and time in enzyme immunoassays for drugs of abuse.

Published information on the major interactive variables of enzymic immunoassays for drugs, whether in urine or serum, is scanty. Using the Syva EMIT-dau Barbiturates assay as an example, we examined the following interactive variables with respect to test response: concentrations of enzyme, antibody, and drug; urine matrix; and time. The results suggest a process for optimizing this type of en...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 23 4  شماره 

صفحات  -

تاریخ انتشار 1999