Comparison between the automated reagin test and reagin screen test methods of VDRL screening tests for syphilis in use in a routine laboratory.
نویسندگان
چکیده
A comparison is made between the automated reagin test (ART) using Technicon AutoAnalyzer equipment and the reagin screen test (RST) introduced by Lederle using a new antigen formulation. Treponemal haemagglutination tests (TPHA) were done simultaneously as second screen tests. The absorbed fluorescent treponemal antibody test (FTA-ABS) was used in all seropositive cases. Altogether 1154 sera were tested; 1028 were negative with all tests, 66 were positive with all tests, 42 were positive with TPHA and negative with ART and RST, and 16 were positive with TPHA and RST and negative with ART. It was concluded that the use of the RST and TPHA together would be the more sensitive screen test.
منابع مشابه
Evaluation of reagin screen, a new serological test for syphilis.
A total of 1,020 serum and plasma specimens were tested using the Venereal Disease Research Laboratory (VDRL), Rapid Plasma Reagin (RPR) card, Reagin Screen (RST) and Fluorescent Treponemal Antibody-Absorption (FTA-ABS) tests. In 257 normal patients, all screening tests were nonreactive; the FTA-ABS test was reactive for one patient. In 588 patients with treated and untreated syphilis, the RST ...
متن کاملComparison of a new rapid plasma reagin card test with the standard rapid plasma reagin 18-mm circle card test and the venereal disease research laboratory slide test for serodiagnosis of syphilis.
The rapid plasma reagin (RPR) card test manufactured by Beckman Instruments, Inc., was compared, qualitatively and quantitatively, with the Venereal Disease Research Laboratory (VDRL) slide test and the standard RPR 18-mm circle card tests for the serodiagnosis of syphilis. Sera from 638 individuals were used in this study. Two pilot lots and two production lots of antigen were submitted by Bec...
متن کاملEvaluation of a new rapid plasma reagin card test as a screening test for syphilis.
This study evaluates the American Dade (Biokit Laboratories) rapid plasma reagin (Dade RPR) card test, currently used in Spain for the diagnosis of syphilis, which has been recently released to the U.S. market. Used as a basis for comparison with the Dade card test were the 18-mm standard rapid plasma reagin (standard RPR) card test and the Venereal Disease Research Laboratory (VDRL) slide test...
متن کاملVisuwell Reagin, a non-treponemal enzyme-linked immunosorbent assay for the serodiagnosis of syphilis.
A urease-based enzyme-linked immunosorbent assay (ELISA) has been developed for the detection of reagin antibodies in serum. Visuwell Reagin (ADI Diagnostics Inc., Rexdale, Ontario, Canada) is a non-treponemal screening test for the serodiagnosis of syphilis which has the benefits of large batch testing, automatability, and objective interpretation of results. Unheated, undiluted sera are incub...
متن کاملEvaluation of automated large-scale screening tests for syphilis.
Two methods of performing serological screening tests for syphilis are compared. One consisted of the Venereal Diseases Reference Laboratory (VDRL) slide test, the cardiolipin Wassermann reaction (CWR), and the Reiter protein complement fixation test (RPCFT) performed manually; the other was a fully automated system using two Technicon AutoAnalyzers (AAII), one for the automated reagin test (AR...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 30 7 شماره
صفحات -
تاریخ انتشار 1977