Entire Removal of Screw-In Pacing Leads 3 Years after Implantation

نویسنده

  • Yasuyuki Shimada
چکیده

OBJECTIVE To report that screw-in type pacing leads can be removed by screw retraction even after a significant anchoring period. PATIENT A 78-year-old woman who visited our hospital for skin erosion over a pacemaker that had been implanted 3 years previously and had migrated from the subclavicular area to the axilla. METHODS Culture revealed a local staphylococcus infection. We placed a new pacemaker system in the contralateral (right) side, removed the old one, inserted a straight type stylet into the leads, and turned the rotator counterclockwise. RESULTS An image monitor confirmed complete retraction of the ventricular lead screw and partial retraction of the atrial lead screw, and we were able to pull out both leads without any resistance. The patient was given antibiotics and discharged 2 days after the surgery. No wound infection was evident at a 3-month follow-up examination. CONCLUSION When a screw-in type pacemaker with a retractor must be removed long after its implantation, screw retraction should be tried before resorting to a removal kit or open heart surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute performance of steroid-eluting screw-in leads for atrial free wall pacing.

The aim of this study was to clarify the acute performance of steroid-eluting screw-in leads in comparison with that of nonsteroid screw-in leads for atrial free wall pacing. In 114 cases (68 males, 46 females, average age 70 years) with atrial free wall pacing by screw-in leads, pacing thresholds and P-wave amplitudes were compared at the time of implantation and 1 week later between 68 cases ...

متن کامل

Acute changes in pacing threshold and R- or P-wave amplitude during permanent pacemaker implantation.

This study examines the changes in pacing threshold and R- or P-wave amplitude during the first 30 minutes after implantation of tined and screw-in leads. The leads examined were those of 1 manufacturer (Medtronic) and consisted of 3 ventricular pacing leads (model numbers 6957 unipolar screw-in [11 patients], 6961 unipolar tined [12 patients] and 6962 bipolar tined [7 patients]) and 1 atrial l...

متن کامل

Stenting of coronary veins: a critical comment.

Daniel Gras was the first to describe coronary venous stenting. Like other authors, he used a coronary stent to fixate a coronary vein (CV) lead in a proximal vein segment when more distal placement led to intractable phrenic nerve stimulation. At the Europace meeting in Lisboa in 2007 and at the 2008 Cardiostim conference in Nice, Szilagyi et al. presented their data on venous stenting in a la...

متن کامل

Lead extraction in children and young adults using different techniques.

OBJECTIVE To describe our experience with removal of pacing lead in children using different techniques. PATIENTS AND METHODS Between 1999 and 2006, removal of 39 leads was attempted in 30 patients: 21 males and 9 females aged 4-21 years (mean 12 +/- 5 years). Sixteen patients had previous corrective cardiac surgery. The leads had been implanted for 46 +/- 31 months (range 1-120 months). The ...

متن کامل

Long-term reliability of sweet-tip type screw-in leads

BACKGROUND Active fixation leads have provided stable atrial and ventricular pacing; however, long-term follow-up data have not been satisfactory. The purpose of this study was to investigate the long-term reliability of active fixation leads and their electrical characteristic stability. METHODS A total of 1196 pacing leads were implanted in 830 patients consecutively between 2002 and 2013. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011