Utility of an implantable right ventricular oxygen saturation-sensing pacemaker for ambulatory cardiopulmonary monitoring.

نویسندگان

  • C P Lau
  • Y T Tai
  • I S Lee
  • M Erickson
  • C Yerich
چکیده

Mixed venous oxygen saturation (SvO2) is a physiologic parameter reflecting cardiac output (CO) and tissue oxygen utilization. An implantable oxygen sensor incorporated in a right ventricular pacing lead has been developed to assess the feasibility of ambulatory monitoring of SvO2 to predict cardiorespiratory parameters. Eight patients with a mean age of 62 +/- 2 years and sinoatrial disease received an SvO2-driven dual-chamber rate-adaptive pacemaker capable of continuous SvO2 measurement. During graded maximal exercise with measurement of oxygen consumption (Vo2), arterial oxygen saturation (SaO2), and telemetered derived SvO2 data, CO was assessed using the Fick principle. The accuracy of the derived CO was compared with CO measured directly by continuous-wave Doppler assessment of the ascending aortic flow. The maximum changes in SvO2 and SaO2 during exercise were 25 +/- 5 and 3 +/- 1%, respectively. SvO2 was significantly correlated with Vo2 (r = 0.9 +/- 0.1, p < 0.001), work done (r = 0.8 +/- 0.1, p < 0.05), and minute ventilation (r = 0.9 +/- 0.1, p < 0.05). Doppler-derived CO was significantly correlated with CO estimated from SvO2 measured (r = 0.8 +/- 0.1, p < 0.05) and is expressed as 46x derived CO +300. Although continuous SvO2 sensing was originally developed to increase pacing rate during exercise, its use can be extended for monitoring cardiopulmonary performance on an ambulatory basis. This may be useful as a direct assessment of cardiopulmonary status in diseased states and also as an objective means to evaluate cardiac response to medical therapy in patients with heart failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous ambulatory monitoring of absolute right ventricular pressure and mixed venous oxygen saturation in patients with heart failure using an implantable haemodynamic monitor: results of a 1 year multicentre feasibility study.

BACKGROUND Implantable sensors that monitor haemodynamics over time may be useful in patients with heart failure. This multicentre study assessed the feasibility of a system that has one sensor measuring absolute pressure and another measuring mixed venous oxygen saturation (SvO(2)). Both sensors were mounted on leads that were implanted in the right ventricle. METHODS Twenty-one patients wit...

متن کامل

Long-term recording of cardiac output via an implantable haemodynamic monitoring device.

Long-term monitoring of central haemodynamics with implanted monitoring systems might be valuable in managing heart failure patients. Such systems offer an opportunity for repeated 'semi-invasive' cardiac output determinations according to the Fick principle. Five patients, four with chronic heart failure and one with chronic pulmonary disease, underwent supine exercise testing during cardiac c...

متن کامل

Pacemaker Twiddler's Syndrome

A 76-yr-old man with unipolar ventricular pacemaker, previously implanted in the right ventricular apex, presented with syncopal attack and twitching of the right pectoralis muscle. He finally was diagnosed as having Twiddler's syndrome. The patient had a pulse rate of 36/min and cannon waves in the neck veins. Chest radiography showed a dislodged pacing lead completely wrapped around the pulse...

متن کامل

Microvolt T-wave alternans in adults with complex congenital heart diseases.

BACKGROUND Sudden cardiac death (SCD) mostly resulting from ventricular arrhythmia remains a cause of mortality in 19-30% of adults with congenital heart defects. Indications for implantable cardioverter-defibrillators in primary prophylaxis are still under research. MicrovoltT wave alternans (MTWA) is one of the SCD risk stratification methods. We determined the incidence of MTWA in these pati...

متن کامل

The Utility of Ambulatory Electrocardiographic Monitoring for Detecting Silent Arrhythmias and Clarifying Symptom Mechanism in an Urban Elderly Population with Heart Failure and Hypertension: Clinical Implications.

Background: Atrial and ventriclar tachyarrhythmias, as well as bradyarrhythmias, in the elderly with heart failure (HF) and/or hypertension (HTN) have been well documented. However, the frequency of these arrhythmias, whether silent or symptomatic, and their association with subsequent cardiac events has not been well defi ned in patients 65 years or older with HF and other cardiovascular risk ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 107 4  شماره 

صفحات  -

تاریخ انتشار 1995