A comparison of Goldmann and Humphrey automated perimetry in patients with glaucoma.
نویسندگان
چکیده
Humphrey automated threshold perimetry (Program 30-2) was performed on 42 eyes of 25 patients with glaucoma to determine both the sensitivity and specificity of automated perimetry in detecting glaucomatous visual field defects. Automated perimetry sensitivity was 90.38%, while automated perimetry specificity was 91%. Fifty-two patients and a technician took part in a survey to determine their preference for either test. Patients generally preferred having Goldmann perimetry. The technician favoured Humphrey automated perimetry. Program 30-2 on the automated perimeter took 25% longer to perform than Goldmann perimetry.
منابع مشابه
A comparison of manual kinetic and automated static perimetry in obtaining ptosis fields.
OBJECTIVE To compare examination time and visual field loss for ptosis fields obtained with manual kinetic (Goldmann) perimetry and automated static (Humphrey) perimetry. METHODS Both eyes of 12 patients with bilateral aponeurogenic ptosis were prospectively examined using Goldmann and Humphrey (ptosis protocol) perimetry with the eyelids ptotic and taped into a normal position. RESULTS Bil...
متن کاملA comparison of tangent screen, goldmann, and humphrey perimetry in the detection and localization of occipital lesions.
OBJECTIVE To compare manual kinetic perimetry with tangent screen and Goldmann techniques and automated static perimetry with the Humphrey Field Analyzer in the detection and localization of occipital lobe lesions. DESIGN Prospective consecutive comparative case series. PARTICIPANTS Twelve patients with well-defined occipital lobe infarcts on magnetic resonance (MR) imaging were studied. ...
متن کاملInvestigating the effects of glaucomatous (POAG) damage on the mVEP parameters
Introduction: Glaucoma is considered as a major cause of irreversible vision loss, worldwide. Glaucoma includes a diverse ophthalmopathies characterized by attenuating the neural and connective tissue segments and eventually progression of specific patterns of visual dysfunction. Currently, perimetry is known as the most accurate diagnostic method in glaucoma and its follow up...
متن کاملA comparison of perimetric results with the Medmont and Humphrey perimeters.
BACKGROUND The Humphrey field analyser (HFA), Humphrey-Zeiss frequency doubling perimeter, and the Medmont automated perimeter (MAP) are three commonly used automated perimeters with threshold achromatic methodologies. Visual field loss may be detected earlier with strategies that target cell lines with reduced redundancy or which suffer selective damage. METHOD To compare these three perimet...
متن کاملGoldmann V Standard Automated Perimetry Underestimates Central Visual Sensitivity in Glaucomatous Eyes with Increased Axial Length
PURPOSE To investigate the effect of axial length (AL) on the structure-function relationship between retinal nerve fiber layer (RNFL) thickness measurements and visual field (VF) sensitivity measured with Goldmann III and V. METHOD There were 85 eyes of 85 patients with primary open angle glaucoma included in the current study. Optical coherence tomography and VF (Humphrey Field Analyzer 24-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 71 7 شماره
صفحات -
تاریخ انتشار 1987