Threshold estimation in single photon emission computed tomography and planar imaging for clinical radioimmunotherapy.

نویسندگان

  • Y E Erdi
  • B W Wessels
  • M H Loew
  • A K Erdi
چکیده

Thresholding is the most widely used organ or tumor segmentation technique used in single photon emission computed tomography (SPECT) and planar imaging for monoclonal antibodies. Selecting the optimal threshold requires a priori knowledge (volumes from CT or magnetic resonance) for the size and contrast level of the organ in question. Failure to select an optimal threshold leads to overestimation or underestimation of the volume and, subsequently, the organ-absorbed dose value in radio-immunotherapy. To investigate this threshold selection problem, we performed a phantom experiment using six lucite spheres ranging from 1 to 117 ml and filled with a uniform activity of 1 microCi/ml Tc-99m. These spheres were placed at the center and off-center locations of a Jasczsak phantom and scanned with a three-headed gamma camera in SPECT and planar modes. Target-nontarget (T:NT) ratios were changed by adding the appropriate activity to the background. A threshold search algorithm with an interpolative background correction was applied to sphere images. This algorithm selects a threshold that minimizes the difference between the true and measured volumes (SPECT) or areas (planar). It was found that for spheres equal to or larger than 20 ml [diameter (D) > 38 mm] and T:NT ratios higher than 5:1, mean thresholds at 42% for SPECT and 38% for planar imaging yielded minimum image segmentation errors, which is in agreement with current literature. However, for small T:NT ratios (< 5:1), the threshold values as high as 71% for SPECT and 85% for planar imaging were substantially different than those fixed thresholds for large spheres (D > 38 mm). Hence, the use of fixed thresholds in low contrasts and with tumor and organ sizes of clinical interest (25 < or = D < or = 50 mm) may result in limited volume estimation accuracy. Therefore, we have provided the investigator a method to obtain the threshold values in which the proper threshold can be selected based on the organ and tumor size and image contrast. By measuring and calibrating the proper threshold value derived through machine-specific phantom measurements, a more accurate volume and activity quantitation can be performed. This, in turn, will provide tumor-absorbed dose optimization and greater accuracy in the measurement of potentially subacute, toxic absorbed doses to normal organs for patients undergoing radioimmunotherapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Brain Single Photon Emission Computed Tomography Scan (SPECT) and Functional MRI in Systemic Lupus Erythematosus Patients with Cognitive Dysfunction: A Systematic Review

Objective(s): Systemic lupus erythematosus (SLE) is an autoimmune disease with a wide range of clinical manifestations. Cognitive dysfunction is one of the manifestations that could present prior to the emergence of any other neuropsychiatric involvements in SLE. Cognitive dysfunction is a subtle condition occurring with ahigh frequency. However, there is no data on the correlation of cognitive...

متن کامل

Neural Imaging Using Single-Photon Avalanche Diodes

Introduction: This paper analyses the ability of single-photon avalanche diodes (SPADs) for neural imaging. The current trend in the production of SPADs moves toward the minimumdark count rate (DCR) and maximum photon detection probability (PDP). Moreover, the jitter response which is the main measurement characteristic for the timing uncertainty is progressing. Methods: The neural imaging pro...

متن کامل

Monte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography

Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...

متن کامل

SPECT-CT fusion in the diagnosis of hyperparathyroidism

Objective(s): In this study, we aimed to analyze the relationship between the diagnostic ability of fused single photon emission computed tomography/computed tomography (SPECT/CT) images in localization of parathyroid lesions and the size of adenomas or hyperplastic glands. Methods: Five patients with primary hyperparathyroidism (PHPT) and 4 patients with secondary hyperparathyroidism (SHPT) we...

متن کامل

Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures

Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cancer research

دوره 55 23 Suppl  شماره 

صفحات  -

تاریخ انتشار 1995