Appropriate Depth of Needle Insertion During Rhomboid Major Trigger Point Block
نویسندگان
چکیده
OBJECTIVE To investigate an appropriate depth of needle insertion during trigger point injection into the rhomboid major muscle. METHODS Sixty-two patients who visited our department with shoulder or upper back pain participated in this study. The distance between the skin and the rhomboid major muscle (SM) and the distance between the skin and rib (SB) were measured using ultrasonography. The subjects were divided into 3 groups according to BMI: BMI less than 23 kg/m(2) (underweight or normal group); 23 kg/m(2) or more to less than 25 kg/m(2) (overweight group); and 25 kg/m(2) or more (obese group). The mean±standard deviation (SD) of SM and SB of each group were calculated. A range between mean+1 SD of SM and the mean-1 SD of SB was defined as a safe margin. RESULTS The underweight or normal group's SM, SB, and the safe margin were 1.2±0.2, 2.1±0.4, and 1.4 to 1.7 cm, respectively. The overweight group's SM and SB were 1.4±0.2 and 2.4±0.9 cm, respectively. The safe margin could not be calculated for this group. The obese group's SM, SB, and the safe margin were 1.8±0.3, 2.7±0.5, and 2.1 to 2.2 cm, respectively. CONCLUSION This study will help us to set the standard depth of safe needle insertion into the rhomboid major muscle in an effective manner without causing any complications.
منابع مشابه
The Effects of Ultrasound-Guided Dry Needling on Patients With Myofascial Pain Syndrome: A Review Study
Objectives: Dry Needling (DN) is a novel and effective intervention for patients with Myofascial Pain Syndrome (MPS). Some characteristics, such as needle penetration depth, needle insertion into the target muscle, and trigger points must be identified in this intervention. The Ultrasound (US)-guided DN is a technique that involves needle insertion at the site of injury and the simulation of ti...
متن کاملبررسی درد محل تزریق، کمردرد و رضایت بیماران از تکنیک اپیدورال در دو روش مدین و پارامدین
Background and purpose: Median epidural block is often done with some difficulty due to pain, ossification of interspinous ligament and improper positioning of patient. Ïn addition, back pain is common with median approach, that may be due to puncture of ligaments on the line of epidural needle passage. Ïn paramedian approach needle dose not pass through ligaments, so back pain can be theoret...
متن کاملEchogenic technology can improve needle visibility during ultrasound-guided regional anesthesia.
Needle tip visualization is fundamental to the safety and efficacy of ultrasound-guided regional anesthesia (UGRA). It can be extremely challenging especially at steep insertion angles. We assessed whether an echogenic needle improved tip visibility during UGRA by anesthesiologists performing their normal in-plane technique. The visibility of the Pajunk Sonoplex (echogenic) and the Pajunk Unipl...
متن کاملA Computational study on the effect of different design parameters on the accuracy of biopsy procedure
Needle insertion is a minimally invasive technique in diagnosing and treating tumors. However, to perform a surgery accurately, the tissue should have minimum amount of displacement during needle insertion so that it reaches the target tissue. Therefore, the tissue membrane has to move less to decrease rupturing under the membrane. In this study, the effect of different design parameters on dis...
متن کاملVirtual Reality simulator for dental anesthesia training in the inferior alveolar nerve block
Objectives This study shows the development and validation of a dental anesthesia-training simulator, specifically for the inferior alveolar nerve block (IANB). The system developed provides the tactile sensation of inserting a real needle in a human patient, using Virtual Reality (VR) techniques and a haptic device that can provide a perceived force feedback in the needle insertion task during...
متن کامل