Effect of the distal-balloon protection system on microembolization during carotid stenting.
نویسندگان
چکیده
BACKGROUND The distal-balloon protection system is being evaluated for its efficacy in preventing embolic neurological events during carotid stenting (CAS). We sought to determine the effect of this system on the frequency of Doppler-detected microembolic signals (MES) during CAS. METHODS AND RESULTS Using transcranial Doppler, we compared the frequency of MES during CAS in 2 groups: 39 patients without distal protection and 37 who used the distal-balloon protection system (GuardWire). There were no significant differences in the clinical or angiographic characteristics between the 2 groups. Three phases with increased MES counts were identified during unprotected CAS; these were stent deployment, predilation, and postdilation (75+/-57, 32+/-36, and 27+/-25 METS, respectively). The distal-balloon protection significantly reduced the frequency of MES during CAS (MES counts: 164+/-108 in the control versus 68+/-83 in the protection group; P=0.002), particularly during these 3 phases. MES in the protection group were detected predominantly during sheath placement, guidewire manipulation, and distal-balloon deflation. CONCLUSION Three phases with increased MES counts were identified during unprotected CAS (eg, stent deployment, predilation, and postdilation). The distal-balloon protection system significantly reduced the frequency of MES during CAS, particularly during these 3 phases.
منابع مشابه
Effect of two different neuroprotection systems on microembolization during carotid artery stenting.
OBJECTIVES This study sought to compare the efficacy of two different cerebral protection systems for the prevention of embolization during carotid artery stenting (CAS) using a transcranial Doppler (TCD) monitoring with the detection of microembolic signals (MES). BACKGROUND Despite the introduction of cerebral protection systems, neurologic complications during CAS cannot completely be prev...
متن کاملMicroembolization during carotid artery stenting in patients with high-risk, lipid-rich plaque. A randomized trial of proximal versus distal cerebral protection.
OBJECTIVES The goal of this study was to compare the rate of cerebral microembolization during carotid artery stenting (CAS) with proximal versus distal cerebral protection in patients with high-risk, lipid-rich plaque. BACKGROUND Cerebral protection with filters partially reduces the cerebral embolization rate during CAS. Proximal protection has been introduced to further decrease embolizati...
متن کاملCarotid artery stenting protected with an emboli containment system.
BACKGROUND AND PURPOSE Fear of distal embolization and stroke has aroused concern regarding carotid stenting. Devices to protect the cerebral circulation may make carotid stenting safer. METHODS A multidisciplinary study group tested a balloon occlusion-aspiration emboli entrapment device in conjunction with carotid stenting. The device consists of an elastomeric balloon on a steerable wire w...
متن کاملClinical Analysis Comparing Efficacy between a Distal Filter Protection Device and Proximal Balloon Occlusion Device during Carotid Artery Stenting.
OBJECTIVE The main concern during transfemoral carotid artery stenting (CAS) is preventing cerebral embolus dislodgement. We compared clinical outcomes and intraprocedural embolization rates of CAS using a distal filter protection device or proximal balloon occlusion device. METHODS From January 2011 to March 2015, a series of 58 patients with symptomatic or asymptomatic internal carotid arte...
متن کاملUse of a large angioplasty balloon for predilation is a risk factor for embolic complications in protected carotid stenting.
Periprocedural neurological complications (PNCs) after carotid stenting were retrospectively analyzed to determine the risk factors with the use of various protective devices. Forty-three lesions in 40 patients were treated by carotid stenting with distal balloon protection for nearly all postdilation procedures and some predilation procedures. The following variables were statistically analyze...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 104 17 شماره
صفحات -
تاریخ انتشار 2001