The purpose of this article was to compare the accuracy of a new impression technique, the triple-layer impression technique (TLIT), with the conventional impression technique (CIT) to fabricate an auricular prosthesis. Fifteen male subjects (aged 22-45 yr) were selected. Ten markings were made on the subject's ear (super aurale [sa], sub aurale [sba], pre aurale [pra], post aurale [poa], A, A1, B, B1, C, and C1) and five measurements (sa-sba, pra-poa, A-A1, B-B1, and C-C1) were made. Custom-made trays were used to record impression in CIT and TLIT. Impressions were made using alginate, and models were cast with type IV gypsum product. Markings were transferred on the cast. Measurements were rechecked on the models. Distribution analysis of difference in measurements between the two impression techniques and the subject's actual values was evaluated. Sign test was used to analyze the statistical significance. Statistically significant differences were found in measurements A-A1, B-B1, and C-C1 between the two techniques when compared with the subject's actual dimensions (p < 0.01). TLIT was found to produce accurate models when compared with CIT. The TLIT used in the study was cost effective, less technique sensitive, and tailor made to reduce chairside orientation time during wax try-in appointments for rehabilitating patients, especially those with unilateral auricular defects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dimensional accuracy of three impression materials by one-step and two-step impression techniques: An in vitro study

Introduction: An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. Methods: In this study, 20 impressions were fabricated for each Vinyl siloxane ether (Identium), condensation silicone (Speedex), and a...

متن کامل

A different wax sculpture technique for implant-retained auricular prosthesis

Replacement of missing ears is a challenging task in which extensive array of materials and techniques have been employed. This article describes a different and simplified procedure for fabricating auricular prostheses very similar to the intact left ear of the patient. A 65-year-old male patient was referred to the Department of Prosthodontics with the loss of the right ear. In this case, the...

متن کامل

Manufacturing Implant Supported Auricular Prostheses by Rapid Prototyping Techniques

Maxillofacial prostheses are usually fabricated on the models obtained following the impression procedures. Disadvantages of conventional impression techniques used in production of facial prosthesis are deformation of soft tissues caused by impression material and disturbance of the patient due to. Additionally production of prosthesis by conventional methods takes longer time. Recently, rapid...

متن کامل

A clinical outcome comparison of the conventional altered cast impression with a modification altered cast impression technique

A clinical outcome comparison of the conventional altered cast impression with a modification altered cast impression technique Dr. M. Farzin *- Dr. F. Bahrani ** - Dr. A. Zareie *** *Assistant Professor of Prosthodontics Dept., Faculty of Dentistry, Shiraz University of Medical Sciences. **Clinical Instructor of Prosthodontics Dept., Faculty of Dentistry, Shiraz University of Medical Sciences....

متن کامل

Fabricating auricular prostheses using three-dimensional soft tissue models.

This article describes a method for fabricating an auricular prosthesis. This procedure uses the contours of the soft tissue surface from computerized tomography scans to fabricate a computer-generated, side-inverted 3-dimensional soft tissue model from a solid block of polyurethane using an Endoplan milling machine. The resultant 3-dimensional soft tissue model can then be used as the basis fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 50 8  شماره 

صفحات  -

تاریخ انتشار 2013