Diagnostic accuracy of SPECT, PET, and MRS for primary central nervous system lymphoma in HIV patients

نویسندگان

  • Mo Yang
  • James Sun
  • Harrison X. Bai
  • Yongguang Tao
  • Xiangqi Tang
  • Lisa J. States
  • Zishu Zhang
  • Jianhua Zhou
  • Michael D. Farwell
  • Paul Zhang
  • Bo Xiao
  • Li Yang
چکیده

BACKGROUND We performed a systematic review and meta-analysis to assess the roles of SPECT, PET, and MRS in distinguishing primary central nervous system lymphoma (PCNSL) from other focal brain lesions (FBLs) in human immunodeficiency virus (HIV)-infected patients. METHODS PubMed, Scopus, and Medline were systematically searched for eligible studies from 1980 to 2016. Two authors extracted characteristics of patients and their lesions using predefined criteria. RESULTS Eighteen studies on SPECT containing 667 patients, 6 studies on PET containing 108 patients, and 3 studies on MRS containing 96 patients were included. SPECT had a pooled sensitivity of 0.92 (95% CI: 0.85-0.96) and specificity of 0.84 (95% CI: 0.74-0.90) in differentiating PCNSL from other FBLs. For the 6 studies that used only pathology and/or serology as the gold standard, the pooled sensitivity was 0.85 (95% CI: 0.72-0.97) and the pooled specificity was 0.73 (95% CI: 0.54-0.92). CONCLUSION SPECT has good diagnostic accuracy for discriminating PCNSL from other FBL-causing disorders in HIV patients. However, the actual sensitivity and specificity of SPECT may be lower than expected if only pathology and/or serology was used as the gold standard. PET may be superior but has less supporting clinical data and is more expensive.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Utility of Thallium-201 Single Photon Emission Computed Tomography and Cerebrospinal Fluid Epstein-Barr Virus Detection Using Polymerase Chain Reaction in the Diagnosis of AIDS-Related Primary Central Nervous System Lymphoma

OBJECTIVE To determine the diagnostic efficiency of thallium-201 single photon emission computed tomography (SPECT) and Epstein-Barr virus (EBV) polymerase chain reaction (PCR) in the differentiation of primary central nervous system lymphoma (PCNSL) from other central nervous system processes in patients with HIV/AIDS. DESIGN/METHODS Over 10 years, 68 thallium-201 SPECT scans were performed ...

متن کامل

Sensitivity of gallium scintigraphy for evaluation of recurrent lymphoma: Comparison of planar and SPECT imaging

  Introduction: Although PET scanning using F-18[FDG] is considered the superior radiotracer for tumnor imaging, Gallium-67 is still in use for some malignancies such as lymphoma and hepatoma. One of the strategies to improve the diagnostic accuracy of Gallium is to perform SPECT which is reported to be more sensitive compared to planar imaging. In this study we compa...

متن کامل

Autoimmune Hemolytic Anemia preceding the Diagnosis of Primary Central Nervous System Lymphoma

In this study, a 2.5-year-old boy suffering from a febrile seizure with normal laboratory tests and a history of immune hemolytic anemia was examined. Brain MRI demonstrated some tumors in the frontal, parietal, and occipital lobe that corroborated the pathology results of primary central nervous system lymphoma for the patient. The patient was treated with high- dose of Methotrexate. Our re...

متن کامل

Diagnostic Accuracy of Squash Preparations in Central Nervous System Tumors

Background & Objectives: The accurate assessment of the diseased tissue is fundamental to the diagnosis and management of disorders of the central nervous system (CNS). The ‛squash’ or ‛crush’ technique has been universally employed in the intraoperative diagnosis of CNS tumors. The aim of our study was to evaluate the accuracy of squash preparation in diagnosing CNS tumors by comparing with hi...

متن کامل

Diagnostic value of using 18F-FDG PET and PET/CT in immunocompetent patients with primary central nervous system lymphoma: A systematic review and meta-analysis

BACKGROUND 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) and PET/CT have become two of the most powerful tools for malignant lymphoma exploration, but their diagnostic role in primary central nervous system lymphoma (PCNSL) is still disputed. The purpose of our study is to identify the usefulness of 18F-FDG PET and PET/CT for detecting PCNSL. RESULTS A total of 129 patie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 96  شماره 

صفحات  -

تاریخ انتشار 2017