The hazard of electrocution during patient monitoring.

نویسنده

  • W R Lee
چکیده

The ever-present hazard in patient monitoring is electrocution resulting in ventricular fibrillation. Fire and explosion hazards are possibilities but seem to be very remote. Iatrogenic electrocution can occur when: (a) more than one piece of electrical equipment is connected to the patient. (b) the distal end of an intracardiac electrode is handled. (c) pericardiocentesis is carried out with ECG monitoring. Under these circumstances, small currents, of the order of 100-200 ,uA, may cause ventricular fibrillation. There is evidence that the ventricular fibrillation threshold is substantially lowered by anoxia and acidosis but it seems to be unaffected by barbiturate anaesthesia. This paper suggests that the physician or surgeon should understand the risks but may need the expert advice of an electrical engineer. Ventricular fibrillation which has occurred under these circumstances requires careful, expert investigation to establish whether or not it was electrically induced.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electric shock during pregnancy.

QUESTION A 24-year-old patient of mine, who was 23 weeks pregnant at the time, suffered a minor electric shock while using her hair dryer. She said she felt the current in her right hand and she was wearing shoes. She was observed in an emergency room for several hours and then discharged home. Is her pregnancy or fetus at risk now or later in the pregnancy? ANSWER There are conflicting repor...

متن کامل

Alternating current electrocution detection and termination by an implantable cardioverter defibrillator.

A patient with an ICD accidentally grasped a power line and was electrocuted. He was unable to release the cable during electrocution though he remained conscious. After receiving a shock from his ICD, the powerline was released. ICD interrogation revealed inappropriate detection of alternating current and delivery of a shock.

متن کامل

A Stochastic Model for Indirect Condition Monitoring Using Proportional Covariate Model

This paper introduces a model to make decision on the maintenance of a mechanical component subject to condition monitoring. A stochastic model is used to determine what maintenance action should be taken at a monitoring check and the follow up inspection times. The condition of component has a stochastic relation with measurements. A new state space model is developed and used, to predict the ...

متن کامل

Suicidal electrocution using a homemade electrocution device.

Electrocutions deaths are mostly accidental, suicidal electrocutions are rarely reported. The records of Forensic Medicine Council of Turkey Bursa Morgue Department reveal second case of suicidal electrocution during the past 20 years. The presented case was a 61 year old man, found by his wife at his home bedroom, using a homemade suicidal electrocution device with bare copper wires. The mecha...

متن کامل

Modeling Parameters Affecting Electrocution Accidents: An 8-Year Study in Tehran Province

Introduction: Electrocution is one of the most important accidents that lead to death. Considering the factors related to the electrocution accidents can reduce the incidence of this type of accidents and their consequences. This study was designed and conducted with the aim of analyzing and modeling the parameters affecting electrocution accidents. Method: This study was a retrospective descr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Postgraduate medical journal

دوره 46 536  شماره 

صفحات  -

تاریخ انتشار 1970