Percutaneous Closure of Mitral Paravalvular Leak Guided by Three-Dimensional Transesophageal Echocardiography

ثبت نشده
چکیده

Reoperation is the method of choice for correcting prosthetic paravalvular leaks. The percutaneous repair of mitral paravalvular leaks might represent an interesting alternative in select cases. The present study reports two cases of mitral paravalvular leaks that were treated with AmplatzerTM Vascular Plug III guided by three-dimensional (3D) transesophageal echocardiography, using the percutaneous approach. The first case involved a 55-year-old male who had undergone five cardiac surgeries (aortic and mitral valve replacements) and presented with New York Heart Association (NYHA) class III heart failure and severe mitral regurgitation. The second case was a 76-year-old male who had undergone two aortic valve replacements; the last procedure was associa ted with mitral valve replacement, which developed into NYHA class IV heart failure and severe mitral regurgitation. This patient had several comorbidities that increased his surgical risk. The procedures were performed percutaneously under general anaesthesia, using the transseptal approach to deploy the plugs, which occluded the paravalvular defects successfully in both cases. DESCRIPTORS: Mitral valve. Heart valve prosthesis. Heart valve prosthesis implantation. Transesophageal echocardiography. Three-dimensional echocardiography. 1 Cardiology specialist in the Brazilian Society of Cardiology. Resident physician in the haemodynamics department at the Instituto Dante Pazzanese de Cardiologia. São Paulo, SP, Brazil. 2 Cardiology specialist in the Brazilian Society of Cardiology. Resident physician in the haemodynamics department at the Instituto Dante Pazzanese de Cardiologia. São Paulo, SP, Brazil. 3 Assistant physician in the echocardiography department at the Instituto Dante Pazzanese de Cardiologia. São Paulo, SP, Brazil. 4 Assistant physician in the echocardiography department at the Instituto Dante Pazzanese de Cardiologia. São Paulo, SP, Brazil. 5 PhD in Science from the Faculdade de Medicina da Universidade de São Paulo. Head of the haemodynamics department at the Instituto Dante Pazzanese de Cardiologia. São Paulo, SP, Brazil. Case Report

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Failed percutaneous closure of a mitral prosthesis paravalvular leak.

A 77-year-old man who had a mechanical prosthetic mitral valve and aortic valve implanted in 1993 presented dyspnea and anemia, and was diagnosed of mitral prosthesis paravalvular leak. The patient was considered at high operative risk owing to his age, severe pulmonary hypertension, chronic renal failure, and previous cardiac surgery. Surgical treatment in his reference hospital was therefore ...

متن کامل

Percutaneous closure of paravalvular mitral regurgitation with Vascular Plug III under the guidance of real-time three-dimensional transesophageal echocardiography.

Transcatheter closure of mitral prosthetic paravalvular leak (PVL) has been hampered by technical challenges and the lack of closure devices specifically designed for this purpose. The oblong cross-sectional shape of the Amplatzer Vascular Plug III device (AVP) may be a more appropriate choice to be deployed for mitral PVL's. Real-time three-dimensional transesophageal echocardiography (RT-3D T...

متن کامل

Real-time three-dimensional TEE-guided repair of a paravalvular leak after mitral valve replacement.

Paravalvular leaks are well-known complications seen following cardiac valve surgery. We report a case in which real-time three-dimensional TEE (3D-TEE) was utilized intraoperatively to identify the number, severity, and precise locations of a paravalvular leak at the time of surgery for mitral valve replacement.

متن کامل

Transapical closure of mitral prosthetic paravalvular leak.

Clinically significant mitral prosthetic paravalvular leaks may occur in up to 5% of patients following surgical mitral valve replacement. Successful closure may offer relief from symptoms of heart failure and hemolysis, but surgical closure is associated with increased morbidity and mortality. Alternative transcatheter closure techniques are being developed. We present a patient who was succes...

متن کامل

First-in-Man Percutaneous Transseptal Closure of Paravalvular Regurgitation After Percutaneous Valve-in-Ring Implantation.

A 73-year-old man with permanent atrial fibrillation, coronary artery disease revascularized with coronary artery bypass grafting, mitral valve repair with a 30-mm Carpentier Physio ring (Edwards Lifesciences, Irvine, California), tricuspid valve repair with a 34-mm Edwards MC3 ring (Edwards Lifesciences), and implantation of a 23-mm CarboMedics aortic valve (Sorin Group, Milan, Italy) in 2008 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013