A systematic review of the clinical effects of reducing dialysate fluid temperature.

نویسندگان

  • Nicholas M Selby
  • Christopher W McIntyre
چکیده

BACKGROUND Intradialytic hypotension (IDH) is a frequent complication of haemodialysis. Reducing the temperature of the dialysis fluid is a simple therapeutic strategy but is relatively underused. This may be due to concerns regarding its effects on symptoms and dialysis adequacy. We performed a systematic review of the literature to examine the effects of cool dialysis on intradialytic blood pressure, and to assess its safety in terms of thermal symptoms and small solute clearance. METHODS We searched the Cochrane Central Register of Controlled Trials, Medline, Embase, Cumulative Index to Nursing and Allied Health Literature, databases of ongoing trials, the contents of four major renal journals as well as hand-searching reference lists. We included all prospective randomized studies that compared any technique of reducing dialysate temperature with standard bicarbonate dialysis. These techniques included an empirical, fixed reduction of dialysate temperature or use of a biofeedback temperature-control device (BTM) to deliver isothermic dialysis or programmed patient cooling. RESULTS A total of 22 studies comprising 408 patients were included (16 studies examined a fixed empirical temperature reduction and six examined BTM). All studies were of crossover design and relatively short duration. IDH occurred 7.1 (95% CI, 5.3-8.9) times less frequently with cool dialysis (both fixed reduction and BTM). Post-dialysis mean arterial pressure was higher with cool-temperature dialysis by 11.3 mmHg (95% CI, 7.7-15.0). No studies reported that cool dialysis led to a reduction in dialysis adequacy as assessed by urea clearance. The frequency and severity of thermal-related symptoms were generally reported inadequately. CONCLUSIONS Reducing the temperature of the dialysate is an effective intervention to reduce the frequency of IDH and does not adversely affect dialysis adequacy. This applies to the fixed reduction of dialysate temperature and BTM. It remains unclear as to what extent cool-temperature dialysis causes intolerable cold symptoms during dialysis. There are no trials comparing fixed empirical temperature reduction with BTM, and no trials examining the long-term effects of cool dialysis on patient outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تأثیر به‌کارگیری محلول دیالیز سرد بر افت فشارخون حین همودیالیز در بیماران مبتلا به مرحله آخر نارسایی کلیه

Background: Hypotension is the most frequent adverse event during hemodialysis. Cool dialysate is a simple and cost effective measure in treating intradialytic hypotension by stabilization of core body temperature. This study was designed to find out the effects of cool dialysate on the frequency of intradialytic hypotension, presenting symptoms and intervention measures used for patients under...

متن کامل

Effect of cool dialysate on vital signs, comfort and adequacy

Abstract Introduction: Cool dialysate solution is an important factor in maintenance of cardio–vascular stability in hemodialysis patients. Objective: This study aimed to determine the effect of dialysate temperature on vital signs, comfort and adequacy of dialysis in hemodialysis patients. Methods: This study is a clinical trial conducted on 30 hemodialysis patients hospitalized in hemod...

متن کامل

Survey of the Relationship Between Obesity Prevalence and Ambient Temperature: A Systematic Review

Introduction: Ambient temperature is considered as a factor affecting on the body's metabolism, So that increase or decrease ambient temperature to the range thermoneutral zone (TNZ) (This temperature is 20.3°C to 23°C for covered people) lead to body metabolic changes, and maybe effective on the increase or reduce the prevalence of obesity. Our aim of this study was to review ...

متن کامل

The Effects of Different Strategies on the Painful Procedure Management, and the Physiological Parameters in Preterm Infants: A Systematic Review

Background: Since preterm infants are subjected to numerous painful and stressful procedures, various strategies reducing the effects during and after painful procedures are required; we aimed to review the effectiveness of the use of different strategies as a primary or adjunctive treatment on the painful procedures, and th...

متن کامل

Prophylactic Effects of Mouthwashes on COVID-19 and its Family Viruses: A Systematic Review

Background and Objectives: One of the most important ways that coronavirus disease 2019 (COVID-19) is transmitted is through respiratory droplets and contact of person to person. Angiotensin-converting enzyme 2 is one of the receptors of this virus, which is abundant in the oral cavity, especially on the epithelial cells of the tongue. By joining to its receptor in the mouth, the virus can infe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 21 7  شماره 

صفحات  -

تاریخ انتشار 2006