Magnetic resonance enterography or video capsule endoscopy – what do Crohn’s disease patients prefer?

نویسندگان

  • Adi Lahat
  • Uri Kopylov
  • Marianne M Amitai
  • Sandra Neuman
  • Nina Levhar
  • Doron Yablecovitch
  • Benjamin Avidan
  • Henit Yanai
  • Iris Dotan
  • Yehuda Chowers
  • Batya Weiss
  • Shomron Ben-Horin
  • Rami Eliakim
چکیده

BACKGROUND Despite differences in the information obtained by capsule endoscopy (CE) and magnetic resonance enterography (MRE), one of these modalities is usually needed when evaluating disease activity. There are no data on patients' preference that would help guide the choice between these two modalities in these instances. AIM To compare patients' tolerance and preference to MRE versus CE. PATIENTS AND METHODS Patients with known small bowel Crohn's disease (CD) in clinical remission (Crohn's disease activity index [CDAI] <150) or with mild symptoms (CDAI <220) were prospectively recruited. All patients underwent MRE followed by CE. Patients were asked to fill out a questionnaire addressing specific points regarding inconvenience during the preparation for the procedures, the procedures, and postprocedures. Side effects and procedure preference were addressed. Questionnaires were included for analysis only when more than 95% of the items were addressed. RESULTS Fifty-six patients fulfilled inclusion criteria. Pre-exam discomfort, during-exam discomfort, nausea, vomiting, bloating, and abdominal pain were all significantly more prominent in MRE as compared to CE (P<0.0001, P<0.0001, P<0.0001, P=0.009, P=0.0002, P<0.0001, respectively). MRE was perceived as a more difficult procedure (P<0.0001). Furthermore, MRE was associated with a specific adverse event - claustrophobia. Seventy-eight percent of patients (44 patients) preferred to repeat CE as compared to 22% (P<0.0001) who preferred MRE. CONCLUSION CE was better tolerated by CD patients compared to MRE and was preferred by 78% of patients. The superior tolerability of CE should be considered along with the diagnostic features, and more data sought when choosing between these two modalities for CD patients for long-term follow-up.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of magnetic resonance enterography and video capsule endoscopy in evaluating small bowel disease.

PURPOSE The goal of this study was to compare magnetic resonance enterography (MRE) and video capsule endoscopy (VCE) in suspected small bowel disease. MATERIALS AND METHODS Nineteen patients with suspected small bowel disease participated in a prospective clinical comparison of MRE versus VCE. Both methods were evaluated separately and in conjunction with respect to a combined diagnostic end...

متن کامل

Comparison of magnetic resonance enterography, capsule endoscopy and gastrointestinal radiography of children with small bowel Crohn’s disease

The aim of this study was to compare magnetic resonance enterography (MRE) findings with those of video capsule endoscopy (VCE) or conventional gastrointestinal radiography (CGR) in pediatric patients with small bowel Crohn's disease. A total of 55 cases of small bowel Crohn's disease that were diagnosed through clinical, laboratory, surgical and histopathological findings were reviewed. Prior ...

متن کامل

Optimal Diagnostic Approaches for Patients with Suspected Small Bowel Disease

While the domain of gastrointestinal endoscopy has made great strides over the last several decades, endoscopic assessment of the small bowel continues to be challenging. Recently, with the development of new technology including video capsule endoscopy, device-assisted enteroscopy, and computed tomography/magnetic resonance enterography, a more thorough investigation of the small bowel is poss...

متن کامل

IRRITABLE BOWEL DISEASE Diagnosis of small bowel Crohn’s disease: a prospective comparison of capsule endoscopy with magnetic resonance imaging and fluoroscopic enteroclysis

Background and aims: The diagnostic yield of capsule endoscopy (CE) compared with magnetic resonance imaging (MRI) in small bowel Crohn’s disease is not well established. We prospectively investigated CE, MRI, and double contrast fluoroscopy in patients with suspected small bowel Crohn’s disease. Methods: Fifty two consecutive patients (39 females, 13 males) were investigated by MRI, fluoroscop...

متن کامل

Effectiveness of Capsule Endoscopy Compared with Other Diagnostic Modalities in Patients with Small Bowel Crohn’s Disease: A Meta-Analysis

Background/Aims As a result of the rapid development of medical diagnostic tools, physicians require concrete evidence to evaluate the effectiveness of the tools. We aimed to investigate the effectiveness and additional diagnostic benefits of capsule endoscopy (CE) in patients with small bowel Crohn's disease (CD). Methods We performed a systematic search of databases, including MEDLINE, EMBA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016