Anterior Tibial Artery Impingement by a Distal Interlocking Screw: A Case Report

نویسنده

  • SAMIR MEHTA
چکیده

A case is presented of a twenty-eight-year-old male with bilateral closed tibial fractures presenting with no right posterior tibial pulse, who was treated with bilateral reamed intramedullary nails. A post-operative arteriogram, to assess injury to the posterior tibial artery due to the initial insult, revealed impingement of the right anterior tibial artery by the most distal screw of the distal locking screws. The screw was exchanged and the patient recovered without further complication. The factors that place the anterior tibial artery at increased risk of injury from distal locking screws are reviewed here.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pseudoaneurysm of anterior tibial artery following tibial nailing: a case report.

Interlocking nailing is a widely accepted and performed treatment for tibial shaft fractures. The addition of percutaneously placed transfixation screws increases the stabilisation provided by intramedullary nailing; however, the technical complexity associated with the procedure has introduced new potential complications. We report a pseudoaneurysm of the anterior tibial artery caused by a pro...

متن کامل

The effect of distal screw orientation on the intrinsic stability of a tibial intramedullary nail.

To compare the intrinsic stability of two distal interlocking screw orientations for tibial nailing of distal third tibial diaphyseal fractures without isthmal support, six Depuy (Warsaw, Indiana) tibial intramedullary nails were implanted in simulated distal tibiae. The constructs received both two parallel (medial to lateral) and two perpendicular (one medial to lateral, one anterior to poste...

متن کامل

The Role of Biplanar Distal Locking in Intramedullary Nailing of Tibial Shaft Fractures

Background: To compare the union times of the uncomplicated tibial shaft fractures, which were distally locked by twocoronal and one sagittal screws and by only two coronal screws.Methods: 45 patients with tibial shaft treated with intramedullary nailing included in this study. 23 of 45 fractureswere treated with uniplanar two distal interlocking (Group 1) and 22 fractures were treated with bip...

متن کامل

Pseudoaneurysm of the anterior tibial artery after interlocking tibial nailing: an unexpected complication

Anterior tibial pseudoaneurysm is a rare complication after interlocking screw insertion in tibial nailing. We present the case of a 28-year-old male patient with this complication with a 6-week delay after tibial nailing of a right tibial fracture type 42-A1 of the Association for the Study of Internal Fixation (AO/ASIF) classification. On presentation to our emergency department, the patient'...

متن کامل

Biomechanical comparison of distal locking screws for distal tibia fracture intramedullary nailing

Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability, 2) which screw orientation/ configuration is the most biomechanically stable, and 3) if three distal interlocking screws provide better stability. Methods: A preliminary experimen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005