Free Vibrations of a Cable with an Attached Mr Damper – Experimental Analysis of Amplitude Dependent Damping

نویسنده

  • Marcin MAŚLANKA
چکیده

This paper presents results of experiments carried out on free vibrations of a cable with an attached magnetorheological (MR) damper. The attention is focused on the analysis of amplitude dependent damping of a cable with an MR damper operating in passive and controlled modes. In the case of the passive system, damping characteristics are nonlinear and display relevant drawbacks of the system. In contrast, in the case of the controlled system, it is revealed that the damping performance achieved with the considered control algorithms is roughly independent of vibration amplitude.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Aeolian Vibrations of Transmission Line Conductors and Extraction of Damper Optimal Placement with a Comprehensive Methodology

Energy balance method is an effective and simple method which is used in the amplitude calculation of Aeolian vibration in transmission lines with Stockbridge damper. However, the accuracy of the results obtained by this method, heavily depends on the assumed mode shapes of the conductor vibration. In this study, by considering an appropriate model for the conductor vibration, a comprehensive m...

متن کامل

Damping Estimation from Free Decay Responses of Cables with MR Dampers

This paper discusses the damping measurements on cables with real-time controlled MR dampers that were performed on a laboratory scale single strand cable and on cables of the Sutong Bridge, China. The control approach aims at producing amplitude and frequency independent cable damping which is confirmed by the tests. The experimentally obtained cable damping in comparison to the theoretical va...

متن کامل

Development of a Self-Powered Magnetorheological Damper System for Cable Vibration Control

A new self-powered magnetorheological (MR) damper control system was developed to mitigate cable vibration. The power source of the MR damper is directly harvested from vibration energy through a rotary permanent magnet direct current (DC) generator. The generator itself can also serve as an electromagnetic damper. The proposed smart passive system also incorporates a roller chain and sprocket,...

متن کامل

A new energy-based method for evaluating the damping properties of cable-damper systems

External dampers and cross-ties are commonly used to control vibrations of stay cables on cable-stayed bridges. While dampers contribute directly to the structural damping of the attached cables, cross-ties mainly help to increase the stiffness of the connected cable system. The idea of incorporating cross-ties with dampers has also been attempted in a few recent applications to benefit from th...

متن کامل

Aeolian Vibrations of Transmission Line Conductors with More than One Damper

To reduce the damages of aeolian vibration of conductors to the power transmission networks, the most common method is installation of Stock-bridge dampers. Estimation of the damper’s dissipated energy is an important factor in determining the number and location of installation of these types of vibration absorbers. This estimation is strongly dependent upon the assumed mode shape of the condu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007