Effects of postural change on transesophageal echocardiography views and parameters in healthy dogs

نویسندگان

  • Seijirow GOYA
  • Tomoki WADA
  • Kazumi SHIMADA
  • Daiki HIRAO
  • Ryuji FUKUSHIMA
  • Norio YAMAGISHI
  • Miki SHIMIZU
  • Ryou TANAKA
چکیده

The purpose of the present study is to investigate the effect of postural change on transesophageal echocardiography (TEE) views and parameters of interest anesthesia monitoring in healthy dogs. Twelve Beagle dogs were anesthetized and randomly positioned in one of four postures: right lateral-recumbency, left lateral-recumbency, supine position and prone position. After examinations in one posture, the same examination was demonstrated in another posture and repeated in all postures. In each posture, several standard TEE views were demonstrated: longitudinal cranial-esophageal aorta long-axis-view, transverse middle-esophageal mitral valve long-axis-view and transgastric middle short-axis-view. Additionally, echocardiographic parameters were attempted to measure, and direct blood pressure monitoring was performed in each view. As a result, oriented views, except for transgastric middle short-axis-view, could be obtained in all postures. Stroke volume and peak early diastolic velocity of mitral inflow were lower in supine position compared with those in right and left lateral-recumbency. Heart rate (HR) and systemic vascular resistance were higher in supine position compared with those in right and left lateral-recumbency. Left ventricular pre-ejection period/left ventricular ejection time corrected and uncorrected by HR were higher in supine position compared with those in right and left lateral-recumbency. In conclusion, longitudinal cranial-esophageal aorta long-axis-view and transverse middle-esophageal mitral valve long-axis-view provide useful information of interest anesthesia monitoring, because of their views enable to certainly obtain TEE parameters in various postures. Furthermore, TEE parameters allow to detect the changes of preload, afterload and HR that occur in supine position dogs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Echocardiographic Measurement of Systolic Time Intervals in Healthy Great Dane Dogs

Objective- to determine the range of systolic times intervals using Pulsed-wave Doppler and m-mode echocardiography in normal, healthy Great Dane dogs. Design- Descriptive study. Animals- Thirty healthy Great Dane dogs. Procedures- This study examined 30 clinically healthy Great Dane dogs by the twodimensional, M-mode and Pulsed-wave Doppler echocardiography. The dogs were awake and unsedated. ...

متن کامل

Follow up the Treatment Process of Mitral Valve Diseases by Radiography and Echocardiography in Dogs

Background: Mitral valve disease is the most common acquired heart disease in dogs. Mitral valve regurgitation (MR) due to endocardiosis is an important cause of morbidity and mortality in dog. Echocardiography as a non-invasive tool is routinely used to evaluate and diagnose different disorders in the heart. Objectives: The purpose of this study is to determine the efficacy of medical treatmen...

متن کامل

Effects of Plantar Flexor Muscles Fatigue on Postural Control during Quiet Stance and External Perturbation in Healthy Subjects

Background: The maintenance of postural control is a key component in dynamic physical activity, especially during muscle fatigue and against external forces. Despite many studies in this field, there is no consensus regarding the effects of plantar flexor muscles fatigue on postural control during different postural tasks.Objective: To evaluate the effects of plantar flexor muscles fatigue on ...

متن کامل

Evaluation of haematological and biochemical changes after short term tramadol usage in healthy dogs

Tramadol is a synthetic, centrally acting opioid analgesic that has the best analgesic efficacy without excessive sedation and significant side effects in the postoperative pain relief in dogs. OBJECTIVES: In this study, hematological and biochemical changes due to short usage of tramadol were assessed in clinically healthy dogs. METHODS: For this purpose, eighteen male mongrel dogs aged 14 to ...

متن کامل

سودوآنوریسم فیستولیزه شده فیبروز بین دریچه ای میترال و آئورت در یک بیمار پس از عمل جراحی بای پس عروق کرونر

Pseudoaneurysm is a rare condition in the region of the fibrous body between the mitral and aortic valve, the mitral-aortic intervalvular fibrosa (MAIVF), that has been reported as a sequela of endocarditis and surgical trauma. MAIVF rarely occurs on native aortic valve after infective endocarditis (IE). It is often fatal because of its rapid progress, high rates of rupture and recurrence, and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 79  شماره 

صفحات  -

تاریخ انتشار 2017