On-chip, real-time, single-copy polymerase chain reaction in picoliter droplets.
نویسندگان
چکیده
The first lab-on-chip system for picoliter droplet generation and PCR amplification with real-time fluorescence detection has performed PCR in isolated droplets at volumes 106 smaller than commercial real-time PCR instruments. The system utilized a shearing T-junction in a silicon device to generate a stream of monodisperse picoliter droplets that were isolated from the microfluidic channel walls and each other by the oil-phase carrier. An off-chip valving system stopped the droplets on-chip, allowing them to be thermally cycled through the PCR protocol without droplet motion. With this system, a 10-pL droplet, encapsulating less than one copy of viral genomic DNA through Poisson statistics, showed real-time PCR amplification curves with a cycle threshold of approximately 18, 20 cycles earlier than commercial instruments. This combination of the established real-time PCR assay with digital microfluidics is ideal for isolating single-copy nucleic acids in a complex environment.
منابع مشابه
A novel picoliter droplet array for parallel real-time polymerase chain reaction based on double-inkjet printing.
We developed and characterized a novel picoliter droplet-in-oil array generated by a double-inkjet printing method on a uniform hydrophobic silicon chip specifically designed for quantitative polymerase chain reaction (qPCR) analysis. Double-inkjet printing was proposed to efficiently address the evaporation issues of picoliter droplets during array generation on a planar substrate without the ...
متن کاملOn-chip single-copy real-time reverse-transcription PCR in isolated picoliter droplets.
The first lab-on-chip system for picoliter droplet generation and RNA isolation, followed by reverse transcription, and PCR amplification with real-time fluorescence detection in the trapped droplets has been developed. The system utilized a shearing T-junction in a fused-silica device to generate a stream of monodisperse picoliter-scale droplets that were isolated from the microfluidic channel...
متن کاملHigh-throughput quantitative polymerase chain reaction in picoliter droplets.
Limiting dilution PCR has become an increasingly useful technique for the detection and quantification of rare species in a population, but the limit of detection and accuracy of quantification are largely determined by the number of reactions that can be analyzed. Increased throughput may be achieved by reducing the reaction volume and increasing processivity. We have designed a high-throughpu...
متن کاملNanolitre droplet array for real time reverse transcription polymerase chain reaction.
Recently, more and more effort has been put into the miniaturization of genetic tests such as quantitative PCR (qPCR), because it is no doubt a powerful tool for molecular diagnosis and quantitative biology. In this paper, we developed a low density nanolitre droplet array generated on a chemical modified silicon chip for gene quantification. Reliable and sensitive two step real time qRT-PCR as...
متن کاملDevelopment and Evaluation of Real-Time Reverse Transcription Polymerase Chain Reaction Test for Quantitative and Qualitative Recognition of H5 Subtype of Avian Influenza Viruses
Avian influenza viruses (AIV) affect a wide range of birds and mammals, cause severe economic damage to the poultry industry, and pose a serious threat to humans. Highly pathogenic avian influenza viruses (HPAI) H5N1 were first identified in Southeast Asia in 1996 and spread to four continents over the following years. The viruses have caused high mortality in chickens and various bird species ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 79 22 شماره
صفحات -
تاریخ انتشار 2007