Global convergence analysis of fast multiobjective gradient-based dose optimization algorithms for high-dose-rate brachytherapy.

نویسندگان

  • M Lahanas
  • D Baltas
  • S Giannouli
چکیده

We consider the problem of the global convergence of gradient-based optimization algorithms for interstitial high-dose-rate (HDR) brachytherapy dose optimization using variance-based objectives. Possible local minima could lead to only sub-optimal solutions. We perform a configuration space analysis using a representative set of the entire non-dominated solution space. A set of three prostate implants is used in this study. We compare the results obtained by conjugate gradient algorithms, two variable metric algorithms and fast-simulated annealing. For the variable metric algorithm BFGS from numerical recipes, large fluctuations are observed. The limited memory L-BFGS algorithm and the conjugate gradient algorithm FRPR are globally convergent. Local minima or degenerate states are not observed. We study the possibility of obtaining a representative set of non-dominated solutions using optimal solution rearrangement and a warm start mechanism. For the surface and volume dose variance and their derivatives, a method is proposed which significantly reduces the number of required operations. The optimization time, ignoring a preprocessing step, is independent of the number of sampling points in the planning target volume. Multiobjective dose optimization in HDR brachytherapy using L-BFGS and a new modified computation method for the objectives and derivatives has been accelerated, depending on the number of sampling points, by a factor in the range 10-100.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Evolutionary and Deterministic Multiobjective Algorithms for Dose Optimization in Brachytherapy

We compare two multiobjective evolutionary algorithms, with deterministic gradient based optimization methods for the dose optimization problem in high-dose rate (HDR) brachytherapy. The optimization considers up to 300 parameters. The objectives are expressed in terms of statistical parameters, from dose distributions. These parameters are approximated from dose values from a small number of p...

متن کامل

Multiobjective anatomy-based dose optimization for HDR-brachytherapy with constraint free deterministic algorithms.

In high dose rate (HDR) brachytherapy, conventional dose optimization algorithms consider multiple objectives in the form of an aggregate function that transforms the multiobjective problem into a single-objective problem. As a result, there is a loss of information on the available alternative possible solutions. This method assumes that the treatment planner exactly understands the correlatio...

متن کامل

Using PSO algorithm optimization for planning 103Pd seeds brachytherapy positions

Radiation therapy, is one of the treatments for cancer. Brachytherapy is a radiotherapeutic technique that a sealed radiation source is placed inside or next to the tissue and has become a mainstream treatment option for cancer. Achieving maximum dose to the gland as well as minimum injury to the adjacent tissues is a basic principle in radiation therapy. Sources configuration must be designed ...

متن کامل

Multiobjective inverse planning for intensity modulated radiotherapy with constraint-free gradient-based optimization algorithms.

We consider the behaviour of the limited memory L-BFGS algorithm as a representative constraint-free gradient-based algorithm which is used for multiobjective (MO) dose optimization for intensity modulated radiotherapy (IMRT). Using a parameter transformation, the positivity constraint problem of negative beam fluences is entirely eliminated: a feature which to date has not been fully understoo...

متن کامل

A Hybrid Evolutionary Algorithm for Multiobjective Anatomy Based Dose Optimization in HDR Brachytherapy

Multiple objectives must be considered in anatomy based dose optimization for high dose rate (HDR) brachytherapy and a large number of parameters must be optimized to satisfy often competing objectives. For objectives expressed solely in terms of dose variances, deterministic gradient-based algorithms can be applied and a weighted sum approach is able to produce a representative set of non-domi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 48 5  شماره 

صفحات  -

تاریخ انتشار 2003