Direct enzymatic assay for %HbA1c in human whole blood samples.

نویسندگان

  • Limin Liu
  • Stefanie Hood
  • Yuping Wang
  • Robert Bezverkov
  • Chao Dou
  • Abhijit Datta
  • Chong Yuan
چکیده

OBJECTIVES Development and validation of a direct enzymatic HbA1c assay that utilizes a single channel on chemistry auto-analyzers without the need to run separate glycated hemoglobin and total hemoglobin assays. DESIGN AND METHODS An enzyme based single channel assay was developed to measure %HbA1c in human whole blood samples. The performance characteristics of the Diazyme Direct Enzymatic HbA1c Assay were evaluated on the Hitachi 917 auto-analyzer using whole blood samples, appropriate controls and a reference lot of manufactured reagents. Accuracy studies were completed by comparing the Direct Enzymatic Assay to existing HPLC and immunoassay methods. Interference testing was performed to determine the effect of total hemoglobin, glycated serum proteins, chemical substances and hemoglobin variants in patient samples. RESULTS The Direct Enzymatic HbA1c Assay showed within run precision and total precision results of < or = 2% CV for both normal and abnormal level samples. Method comparison studies showed that there was a good correlation between the Direct Enzymatic HbA1c and the HPLC (R(2)=0.98) or the immunoassay (R(2)=0.97) methods. The assay measured within the range of 4-16% HbA1c and showed excellent performance with variant hemoglobin in samples. CONCLUSIONS Diazyme Direct Enzymatic HbA1c Assay is accurate and precise when compared to currently marketed medical devices. The assay is designed to report %HbA1c values directly without need for a separate measurement of total hemoglobin and is not adversely affected by interferences from common hemoglobin variants in samples. It is a cost effective, user-friendly method and is adaptable to most general chemistry analyzers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

C3ay40165k 2461..2469

Recent studies have shown that blood HbA1c levels alone may not accurately reflect serum glucose concentrations in all diabetic patients. For certain diabetic patients, there exists a glycation gap. It was reported that the glycation gap information obtained by measuring HbA1c and glycated serum protein (GSP) or glycated albumin (GA) together may improve evaluation of diabetic patients by more ...

متن کامل

Glycated haemoglobin A1c measurement in stored whole blood sample is reliable for clinical use.

Glycated haemoglobin A1c (HbA1c) gives an integrated plasma glycaemia for the previous 2-3 months and its measurement is central in the management of diabetic patients. However in many developing countries because kits/regents or expertise for HbA1c measurement are not always available and the test must be conducted on fresh whole blood samples, HbA1c tests are not routinely performed Thus, thi...

متن کامل

Performance of the Roche second generation hemoglobin A1c immunoassay in the presence of HB-S or HB-C traits.

Blood HbA1c determination is a powerful tool for the evaluation and management of patients with diabetes mellitus. Many HbA1c analytical methods demonstrate bias in samples from patients with hemoglobinopathies. This study evaluated the analytical performance of Roche Diagnostics' 1st and 2nd generation HbA1c assays in patients with or without hemoglobinopathies whose HbA1c levels were elevated...

متن کامل

Study of Radioprotective Effect of Green Tea against Gamma Irradiation Using Micronucleus Assay on Binucleated Human Lymphocytes

Objective(s)The aim of this study was to investigate the radioprotective effect of green tea against genotoxicity induced by gamma irradiation in cultured blood lymphocytes from 5 human volunteers.Materials and MethodsPeripheral blood samples were collected from volunteers before and 1, 3 and 5 hr after drinking a decoction 4 g green tea in 280 ml boiling water for 5 constitutive days with the ...

متن کامل

A lateral flow immunosensor for direct, sensitive, and highly selective detection of hemoglobin A1c in whole blood.

An immunosensor that operates based on the principles of lateral flow was developed for direct detection of hemoglobin A1c (HbA1c) in whole blood. We utilized colloidal gold-functionalized antibodies to transduce the specific signal generated when sandwich immuno-complexes were formed on the strip in the presence of HbA1c. The number and intensity of the test lines on the strips indicate normal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical biochemistry

دوره 41 7-8  شماره 

صفحات  -

تاریخ انتشار 2008