AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology.

نویسندگان

  • C M Ma
  • C W Coffey
  • L A DeWerd
  • C Liu
  • R Nath
  • S M Seltzer
  • J P Seuntjens
چکیده

The American Association of Physicists in Medicine (AAPM) presents a new protocol, developed by the Radiation Therapy Committee Task Group 61, for reference dosimetry of low- and medium-energy x rays for radiotherapy and radiobiology (40 kV < or = tube potential < or = 300 kV). It is based on ionization chambers calibrated in air in terms of air kerma. If the point of interest is at or close to the surface, one unified approach over the entire energy range shall be used to determine absorbed dose to water at the surface of a water phantom based on an in-air measurement (the "in-air" method). If the point of interest is at a depth, an in-water measurement at a depth of 2 cm shall be used for tube potentials > or = 100 kV (the "in-phantom" method). The in-phantom method is not recommended for tube potentials < 100 kV. Guidelines are provided to determine the dose at other points in water and the dose at the surface of other biological materials of interest. The protocol is based on an up-to-date data set of basic dosimetry parameters, which produce consistent dose values for the two methods recommended. Estimates of uncertainties on the final dose values are also presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Energy response of EBT3 radiochromic films: implications for dosimetry in kilovoltage range

The objective of this study is to evaluate the suitability of recently introduced radiochromic film EBT3 for clinical dosimetry in the kilovoltage (kV) range. For this purpose, a kV X-ray irradiator, X RAD 320ix in the range 70 to 300 kVp, a clinical 60Co source, a 6 MV and an 18 MV X-ray clinical beam from a Varian linear accelerator were calibrated following AAPM dosimetry protocols. EBT3 fil...

متن کامل

Dosimetry intercomparison using a 35-keV X-ray synchrotron beam.

The purpose of this study was to compare dose measurements using ion chamber and radiochromic film dosimetry for a 35-keV synchrotron beam useful for Auger electron therapy. A 1.3-GeV electron beam, transported through a 3-pole superconducting wiggler magnet, produced a polychromatic photon beam from which a 35-keV beam (3.3 mm Al HVL) was selected using a monochromator. A 2.8 cm x 2.5 cm field...

متن کامل

بررسی اثر ناهمگنی بافت در دوز دریافتی پرتوهای اورتو ولتاژ در ناحیه نخاع گردنی موش صحرایی

    Background & Aim: The most important physical quantity of irradiation to predict and evaluate the response of biological samples to irradiation is absorbed dose. Recently, according to ICRU(International Commission on Radiation Units and Measurements) reports, determination of absorbed dose with 3.5% accuracy is recommended. Dose distribution is usually estimated in homogeneous mass by unit...

متن کامل

Induction of cancer stem-like cells in A549 cells after exposure to carbon ions and X-rays

Background: Cancer stem-like cells (CSCs) play a crucial role in the initiation, progression, and recurrence of cancer. Evidence indicates that the high linear energy transfer (LET) carbon ion beam is more effective against CSCs than the conventional X-ray beam. Carbon ion radiotherapy is considered as a promising cancer strategy, however, information about whether, or not, new CSCs are induced...

متن کامل

Image guided IMRT dosimetry using anatomy specific MOSFET configurations

We have investigated the feasibility of using a set of multiple MOSFETs in conjunction with the mobile MOSFET wireless dosimetry system, to perform a comprehensive and efficient quality assurance (QA) of IMRT plans. Anatomy specific MOSFET configurations incorporating 5 MOSFETs have been developed for a specially designed IMRT dosimetry phantom. Kilovoltage cone beam computed tomography (kV CBC...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 28 6  شماره 

صفحات  -

تاریخ انتشار 2001