In-stent restenosis in small coronary arteries: impact of strut thickness.

نویسندگان

  • Carlo Briguori
  • Cristiano Sarais
  • Paolo Pagnotta
  • Francesco Liistro
  • Matteo Montorfano
  • Alaide Chieffo
  • Fabio Sgura
  • Nicola Corvaja
  • Remo Albiero
  • Goran Stankovic
  • Costantinos Toutoutzas
  • Erminio Bonizzoni
  • Carlo Di Mario
  • Antonio Colombo
چکیده

UNLABELLED OBJECTIVES; We sought to evaluate whether strut thickness may impact the restenosis rate after stent implantation in small coronary arteries. BACKGROUND Small vessel size (<3.0 mm) is an independent risk factor for the occurrence of in-stent restenosis. It has been reported that vessel damage induced during stent deployment is an important factor in restenosis. METHODS From our database, we selected all patients who had successful stenting in small native vessels, with angiographic follow-up available, between March 1996 and April 2001. The strut was defined as thin when <0.10 mm and thick when > or = 0.10 mm. According to these criteria, we identified two subgroups: a thin group and a thick group. RESULTS A total of 821 (57%) of the 1,447 patients had angiographic follow-up available and were included in the analysis. The thin group included 400 patients with 505 lesions. The thick group included 421 patients with 436 lesions. The restenosis rate was 28.5% in the thin group and 36.6% in the thick group (p = 0.009; odds ratio [OR] 1.44, 95% confidence interval [CI] 1.09 to 1.90). The study group was classified into three subgroups according to the reference vessel diameter: < or = 2.50 mm, 2.51 to 2.75 mm and 2.76 to 2.99 mm. Strut thickness influenced the restenosis rate only in the subgroup with a reference vessel diameter between 2.76 and 2.99 mm, with rates of 23.5% in the thin group and 37% in the thick group (p = 0.006). By logistic regression analysis, predictors of restenosis were stent length (OR 1.03, 95% CI 1.01 to 1.04; p = 0.001), strut thickness (OR 1.68, 95% CI 1.23 to 2.29; p = 0.001) and diabetes mellitus (OR 2.10, 95% CI 1.21 to 3.68; p = 0.007). CONCLUSIONS This study supports that strut thickness is an independent predictor of restenosis in coronary arteries with a reference diameter of 2.75 to 2.99 mm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predictors of restenosis after implantation of 2.5 mm stents in small coronary arteries.

BACKGROUND The results of stent implantation for small coronary disease have been inconclusive. The purpose of the present study was to evaluate the factors in predicting the risk of angiographic restenosis after 2.5-mm stent implantation for small coronary arteries. METHODS AND RESULTS The study group comprised 134 consecutive patients who had a reference small coronary artery with diameter ...

متن کامل

Multi-scale simulations of the dynamics of in-stent restenosis: impact of stent deployment and design.

Neointimal hyperplasia, a process of smooth muscle cell re-growth, is the result of a natural wound healing response of the injured artery after stent deployment. Excessive neointimal hyperplasia following coronary artery stenting results in in-stent restenosis (ISR). Regardless of recent developments in the field of coronary stent design, ISR remains a significant complication of this interven...

متن کامل

Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial.

OBJECTIVES We tested the hypothesis that thinner-strut stents are associated with a reduced rate of restenosis when comparing two stents with different design. BACKGROUND We have previously shown that, for two stents with similar design, the risk for restenosis is dependent on the strut thickness. It is unknown whether strut thickness preserves its relevance as a determinant of restenosis eve...

متن کامل

Morphological predictors of restenosis after coronary stenting in humans.

BACKGROUND Experimental studies suggest that arterial injury and inflammation lead to increased neointimal growth after stenting. Despite the increased use of coronary stents in humans, there are only limited pathological data on the morphological features of in-stent restenosis. METHODS AND RESULTS Detailed histology was performed on 116 stents, implanted > or =90 days in 87 coronary arterie...

متن کامل

Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial.

BACKGROUND Increased thrombogenicity and smooth muscle cell proliferative response induced by the metal struts compromise the advantages of coronary stenting. The objective of this randomized, multicenter study was to assess whether a reduced strut thickness of coronary stents is associated with improved follow-up angiographic and clinical results. METHODS AND RESULTS A total of 651 patients ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 40 3  شماره 

صفحات  -

تاریخ انتشار 2002