Comparison of free breathing versus breath-hold in perfusion imaging using dynamic volume CT

نویسندگان

  • Sonja Kandel
  • Henning Meyer
  • Patrik Hein
  • Alexander Lembcke
  • Jens-C. Rueckert
  • Patrik Rogalla
چکیده

OBJECTIVES To compare two scanning protocols (free breathing versus breath-hold) for perfusion imaging using dynamic volume computed tomography (CT) and to evaluate their effects on image registration. MATERIAL AND METHODS Forty patients underwent dynamic volume CT for pancreatic perfusion analysis and were randomly assigned to either a shallow-breathing (I) or breath-hold (II) group. Both dynamic CT protocols consisted of 17 low-dose volumetric scans. Rigid image registration was performed by using the volume with highest aortic attenuation as reference. All other volumes were visually matched with the pancreatic lesion serving as the volumetric region of interest. The overall demand for post-processing per patient was calculated as the median of three-dimensional vector lengths of all volumes in relation to the relative patient origin. The number of volumes not requiring registration was recorded per group. RESULTS Registration mismatch for groups I and II was 2.61 mm (SD, 1.57) and 4.95 mm (SD, 2.71), respectively (P < 0.005). Twenty-eight volumes in group I (8.2%) and 47 volumes in group II (14.1%) did not require manual registration (P = 0.014). CONCLUSION Shallow breathing during dynamic volume CT scanning reduces the overall demand for motion correction and thus may be beneficial in perfusion imaging of the pancreas MAIN MESSAGES • Shallow breathing during perfusion CT scanning reduces the overall demand for motion correction. • Shallow breathing may be beneficial in perfusion imaging of the pancreas. • Image registration is crucial for CT perfusion imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of pulmonary perfusion with breath-hold and free-breathing dynamic contrast-enhanced magnetic resonance imaging: quantification and reproducibility.

OBJECTIVES The purpose of this study was to investigate whether quantification of pulmonary perfusion from dynamic contrast-enhanced magnetic resonance imaging (DCE MRI) yields more reproducible results with data acquired during free breathing than with data from conventional breath-hold measurements. MATERIAL AND METHODS Ten healthy male volunteers underwent 2 imaging sessions at a clinical ...

متن کامل

Localized spatio-temporal constraints for accelerated CMR perfusion.

PURPOSE To develop and evaluate an image reconstruction technique for cardiac MRI (CMR) perfusion that uses localized spatio-temporal constraints. METHODS CMR perfusion plays an important role in detecting myocardial ischemia in patients with coronary artery disease. Breath-hold k-t-based image acceleration techniques are typically used in CMR perfusion for superior spatial/temporal resolutio...

متن کامل

Free-breathing liver perfusion imaging using 3-dimensional through-time spiral generalized autocalibrating partially parallel acquisition acceleration.

OBJECTIVES The goal of this study was to develop free-breathing high-spatiotemporal resolution dynamic contrast-enhanced liver magnetic resonance imaging using non-Cartesian parallel imaging acceleration, and quantitative liver perfusion mapping. MATERIALS AND METHODS This study was approved by the local institutional review board and written informed consent was obtained from all participant...

متن کامل

Free-breathing myocardial perfusion MRI using SW-CG-HYPR and motion correction.

First-pass perfusion MRI is a promising technique to detect ischemic heart disease. Sliding window (SW) conjugate-gradient (CG) highly constrained back-projection reconstruction (HYPR) (SW-CG-HYPR) has been proposed to increase spatial coverage, spatial resolution, and SNR. However, this method is sensitive to respiratory motion and thus requires breath-hold. This work presents a non-model-base...

متن کامل

CT perfusion in oncology: how to do it

Robust technique and accurate data analysis are required for reliable computed tomography perfusion (CTp) imaging. Multislice CT is required for high temporal resolution scanning; 16-slice (or 64-slice) scanners are preferred for adequate volume coverage. After tumour localization, the volume of CTp imaging has to be positioned to include the maximum visible area of the tumour and an adequate a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2012