Measurement of carotid blood flow in man and its clinical application.
نویسندگان
چکیده
With the use of a new ultrasonic volume flow meter (VFM), over 8000 measurements of common carotid blood flow were made in 120 normal control subjects and 550 patients with various neurological disease. The accuracy of the flow meter in measuring blood flow on an experimental model ranged from 93 to 97%. In normal subjects, common carotid blood flow varies with age. It increased from newborn to age 20 and gradually decreased thereafter. In normal healthy subjects, the flow varies within +/- 6.7% (2SD) at one sitting (intrasession) and +/- 21.2% (2SD) from week to week (intersession study). Carotid blood flow varies linearly with PaCO2 and increased markedly in response to endotracheal intubation. In healthy adults, the flow ratio between the two common carotid arteries is 1.07 +/- 0.052. This ratio increases in patients with transient ischemic attacks to 1.28 +/- 0.23 (p less than 0.05) and in patients with intracranial space occupying lesions to 1.46 +/- 0.39, (p less than 0.01). In 26 consecutive cases of carotid endarterectomies, the preoperative common carotid blood volume flow was 5.1 +/- 1.0 cc/sec. All cases preoperatively had at least 30% stenosis and ranged from 30 to 100% stenosis. The carotid blood volume was significantly increased post-operatively (p less than 0.001). The overall accuracy in detecting carotid and cerebral arterial disease is 89% with sensitivity of 96% and the specificity of 71%. Our clinical experience indicates that this device is not only a valuable noninvasive diagnostic tool for evaluation of carotid disease but also appears to be useful in assessing cerebral blood flow.
منابع مشابه
Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کاملبرآورد سرعت موج پالس با استفاده از پارامترهای شریانی استخراج شده از تصاویر فراصوتی کاروتید
Background & Objective : Several indices have been introduced to estimate arterial stiffness that based on changes in brachial blood pressure. But because of the error resulted by the substitution of brachial blood pressure instead of the other central arteries, such as carotid, it will be very important to present elastic parameter based on the mechanical models without any emphasis on brach...
متن کاملReport of a Variation of the Right Common Carotid Artery
Carotid artery is the most important artery that carries the major part of the blood supply to the head and neck. The branching of the common carotid artery usually occurs at the upper edge of the thyroid cartilage. The placement of carotid sinus has also increased its importance in this area. Considering the clinical importance of knowledge about carotid artery variations, this case is reporte...
متن کاملVibration Analysis of Carotid Arteries Conveying Non-Newtonian Blood Flow Surrounding by Tissues
The high blood rate that often occurs in arteries may play a role in artery failure and tortuosity which leads to blackouts, transitory ischemic attacks and other diseases. However, vibration and instability analysis of carotid arteries are lacking. The objective of this study is to investigate the vibration and instability of the carotid arteries conveying blood under axial tension with surrou...
متن کاملTissue blood flow measurement by laser Doppler technique
Measurement of blood flow and the effects of different factors on tissue blood flow are important fields of research in physiology and pharmacology. So far, different methods have been innovated, using laser light is the Last one. In this article history, principles and specifications of laser technique along with its advantages and disadvantages ( in comparison with other methods) are revie...