Analytical approaches for Hg determination in wastewater samples by means of total reflection X-ray fluorescence spectrometry.

نویسندگان

  • E Marguí
  • P Kregsamer
  • M Hidalgo
  • J Tapias
  • I Queralt
  • C Streli
چکیده

At present, there is a considerable interest in Hg monitoring in wastewater samples due to its widespread occurrence and the high toxicity of most of its compounds. Hg determination in water samples by means of total reflection X-ray fluorescence spectrometry (TXRF) entails some difficulties due to the high vapor pressure and low boiling point of this element that produce evaporation and loss of Hg from the surface of the reflector during the drying process, commonly used for sample preparation in TXRF analysis. The main goal of the present research was to develop a fast and simple chemical strategy to avoid Hg volatilization during the analysis of wastewater samples by TXRF spectrometry. Three different analytical procedures were tested for this purpose: (i) increasing the viscosity of the wastewater sample by adding a non-ionic surfactant (Triton X-114), (ii) Hg immobilization on the quartz reflectors using the extractant tri-isobutylphosphine (Cyanex 471X) and (iii) formation of a stable and non-volatile Hg complex into the wastewater sample. The best analytical strategy was found to be the formation of a Hg complex with thiourea (pH=10) before the deposition of 10 microL of sample on the reflector for following TXRF analysis. Analytical figures of merit such as linearity, limits of detection, accuracy and precision were carefully evaluated. Finally, the developed methodology was applied for the determination of Hg in different types of wastewater samples (industrial effluents, municipal effluents from conventional systems and municipal effluents from constructed wetlands).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of halide impurities in ionic liquids by total reflection X-ray fluorescence spectrometry.

The determination and quantification of halide impurities in ionic liquids is highly important because halide ions can significantly influence the chemical and physical properties of ionic liquids. The use of impure ionic liquids in fundamental studies on solvent extraction or catalytic reactions can lead to incorrect experimental data. The detection of halide ions in solution by total reflecti...

متن کامل

Application of total reflection X-ray fluorescence spectrometry to small glass fragments.

Total reflection X-ray fluorescence spectrometry (TXRF) has been applied for trace elemental analysis of small glass fragments. A small glass sample (a fragment with weight less than 0.5 mg) was decomposed by 100 microg of HF/HNO3 acid; the material was condensed to 10 microl and was dried on a Si wafer. Since the size of the dried residue on the Si wafer was less than 1 cm in diameter, an inci...

متن کامل

Evaluation of the protein concentration in enzymes via determination of sulfur by total reflection X-ray fluorescence spectrometry limitations of the method

Ž . Total reflection X-ray fluorescence spectrometry TXRF offers many advantages for the identification of trace elements in biological samples like proteins, enzymes, tissues or plants. Because of difficult and time consuming isolations and cleaning procedures enzyme samples are often available in small amounts only. Using TXRF without any preliminary treatment, a ‘screening’ of such samples t...

متن کامل

A new vapor generation system for mercury species based on the UV irradiation of mercaptoethanol used in the determination of total and methyl mercury in environmental and biological samples by atomic fluorescence spectrometry.

A new vapor generation system for mercury (Hg) species based on the irradiation of mercaptoethanol (ME) with UV was developed to provide an effective sample introduction unit for atomic fluorescence spectrometry (AFS). Preliminary investigations of the mechanism of this novel vapor generation system were based on GC-MS and FT-IR studies. Under optimum conditions, the limits of determination for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 82 2  شماره 

صفحات  -

تاریخ انتشار 2010