Femoral stem wear in cemented total hip replacement.
نویسندگان
چکیده
The great success of cemented total hip replacement to treat patients with endstage osteoarthritis and osteonecrosis has been well documented. However, its long-term survivorship has been compromised by progressive development of aseptic loosening, and few hip prostheses could survive beyond 25 years. Aseptic loosening is mainly attributed to bone resorption which is activated by an in-vivo macrophage response to particulate debris generated by wear of the hip prosthesis. Theoretically, wear can occur not only at the articulating head-cup interface but also at other load-bearing surfaces, such as the stem-cement interface. Recently, great progress has been made in reducing wear at the head-cup interface through the introduction of new materials and improved manufacture; consequently femoral stem wear is considered to be playing an increasingly significant role in the overall wear of cemented total hip replacement. In this review article, the clinical incidences of femoral stem wear are comprehensively introduced, and its significance is highlighted as a source of generation of wear debris and corrosion products. Additionally, the relationship between femoral stem surface finish and femoral stem wear is discussed and the primary attempts to reproduce femoral stem wear through in-vitro wear testing are summarized. Furthermore, the initiation and propagation processes of femoral stem wear are also proposed and a better understanding of the issue is considered to be essential to reduce femoral stem wear and to improve the functionality of cemented total hip replacement.
منابع مشابه
Generation of Fretting Wear Debris at the Stem– Cement Interface in Total Hip Replacment
Fretting wear debris generated at the stem–cement interface has nowadays been considered to play an important role in the overall failure of cemented total hip replacement (THR). Those wear debris within a certain size range would transport along bone cement deficiencies to bone tissue, resulting in a significant bone resorption and subsequent aseptic loosening of the femoral component, which i...
متن کاملReverse hybrid and cemented hip replacement compared using radiostereometry and dual-energy X-ray absorptiometry
BACKGROUND AND PURPOSE Total hip replacement (THR) with a reverse hybrid (RH), a combination of a cemented polyethylene cup and a cementless femoral stem, has been increasingly used in Scandinavia. In a randomized trial, we compared an RH THR with a proximal hydroxyapatite- (HA-) coated stem to a conventional cemented THR. Both groups received the same polyethylene cup. PATIENTS AND METHODS 5...
متن کاملHip Arthroplasty and its Revision in a Child: Case Report and Literature Review
Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...
متن کاملBilateral atypical femoral fracture and end-stage arthritis of the hip, treated with total hip arthroplasty
The prolonged use of bisphosphonates has been associated with an increased rate of atypical femoral fracture. A 77-year-old woman with prolonged bisphosphonate use presented to our office with groin pain and end-stage arthritis, She was scheduled for a total hip replacement. Before the surgery and with minimal trauma, the patient then suffered a displaced atypical femoral fracture. She underwen...
متن کاملA novel test method for evaluation of the abrasive wear behaviour of total hip stems at the interface between implant surface and bone cement.
After total hip replacement, some cemented titanium stems show above-average early loosening rates. Increased release of wear particles and resulting reaction of the peri-prosthetic tissue were considered responsible. The objective was to develop a test method for analysing the abrasive wear behaviour of cemented stems and for generating wear particles at the interface with the bone cement. By ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
دوره 222 5 شماره
صفحات -
تاریخ انتشار 2008