Valvular Heart Disease Pathological Healing Response of Explanted MitraClip Devices

نویسنده

  • Elena Ladich
چکیده

Background—The safety and effectiveness of the MitraClip device (Abbott Vascular, Menlo Park, CA) is being evaluated in the Endovascular Valve Edge-to-Edge Repair Study (EVEREST) clinical studies. The healing response after device implantation has not previously been characterized in humans. Methods and Results—A total of 67 explanted devices (implantation duration, 1 to 1878 days) from 50 patients were submitted for histological evaluation. Explants were analyzed in 4 implantation intervals: acute ( 30 days; n 7), subacute (31 to 90 days; n 23), chronic (91 to 300 days; n 18), and long term ( 300 days; n 19). The acute healing response consisted of platelet/fibrin deposition. The subacute response exhibited granulation tissue with early fibrous encapsulation (pannus). The chronic response was characterized by various degrees of tissue bridging between the device arms. The long-term healing response demonstrated collagen-rich matrix (by type I collagen), incorporating the device components with complete encapsulation by organized, fibrous growth. In long-term devices with minimal surgical disruption, a fibrous tissue bridge (mean area, 7.39 4.3 mm) was observed over and between the device arms, resulting in atrial tissue continuity between the 2 valve leaflets. Devices demonstrated no evidence of endocarditis, mechanical wear, component fracture, or corrosion up to the time of explantation (median, 119 days; first and third quartiles, 42 and 365 days). Conclusions—In all patients, device mechanical integrity was maintained up to the time of explantation. Four phases of physiological healing were observed: platelet and fibrin deposition, inflammation, granulation tissue, and finally, fibrous encapsulation. Long-term device fibrous encapsulation with extension over adjacent mitral leaflets and tissue bridge formation adds structural stability. Clinical Trial Registration—URL: http://clinicaltrials.gov/show/NCT00209274. Unique identifiers: NCT00209339 and NCT00209274. (Circulation. 2011;123:1418-1427.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First Reported Case of MitraClip Placement Due to Mitral Valve Flail in the Setting of Cardiac Amyloidosis.

Amyloidosis is a protein misfolding disorder characterized by aggregation and deposition of amyloid fibrils in tissues and organs disrupting architecture and function. Although this disorder often results in a restrictive cardiomyopathy with diffuse biventricular thickening, biatrial dilation, and conduction disease, clinically significant valvular heart disease is rarely described. The MitraCl...

متن کامل

Percutaneous mitral valve repair: The MitraClip device

Chronic mitral regurgitation (MR) is the most common cardiac valvular disease with more than 4 million people in the United States alone suffering from moderate or severe MR. Left untreated, chronic MR results in serious consequences. Surgical correction with mitral valve repair or replacement remains the mainstay of therapy for MR. Nevertheless, a large proportion of patients may not be offere...

متن کامل

Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery

Background: Pulmonary complications following valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and functional capacity to Positive End-Expiratory Pressure device in patients who underwent valvular hea...

متن کامل

[Percutaneous treatment of mitral valve regurgitation: Initial experience with the MitraClip device].

INTRODUCTION Mitral regurgitation (MR) is the most common valvular disease and has recently become the target of a number of percutaneous approaches. The MitraClip is virtually the only device for which there is considerable experience, with more than 20,000 procedures performed worldwide. OBJECTIVE To describe our initial experience of the percutaneous treatment of MR with the MitraClip devi...

متن کامل

Percutaneous reduction of mitral valve regurgitation using the MitraClip system – immediate and 90-day follow-up of 3 cases

Treatment of hemodynamically significant valvular heart diseases has been the domain of cardiac surgery for decades. However, a promising novel method is the MitraClip system, involving percutaneous connection of insufficient valve leaflets with special cobalt-chrome clips. Our study presents clinical characteristics, course of treatment with the MitraClip system, and immediate and 90-day clini...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011