A reconstruction method for equidistant fan beam differential phase contrast computed tomography.

نویسندگان

  • J Fu
  • P Li
  • Q L Wang
  • S Y Wang
  • M Bech
  • A Tapfer
  • D Hahn
  • F Pfeiffer
چکیده

We report a reconstruction method, called a back-projection filtered (BPF) algorithm, for fan beam differential phase contrast computed tomography (DPC-CT) with equidistant geometrical configuration. This work comprises a numerical study of the algorithm and its experimental verification with a three-grating interferometer and an x-ray tube source. The numerical simulation and experimental results demonstrate that the proposed method can deal with several classes of truncated datasets. It could be of interest in future medical phase contrast imaging applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Usability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter

Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...

متن کامل

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

3D Algebraic Iterative Reconstruction for Cone-Beam X-Ray Differential Phase-Contrast Computed Tomography

Due to the potential of compact imaging systems with magnified spatial resolution and contrast, cone-beam x-ray differential phase-contrast computed tomography (DPC-CT) has attracted significant interest. The current proposed FDK reconstruction algorithm with the Hilbert imaginary filter will induce severe cone-beam artifacts when the cone-beam angle becomes large. In this paper, we propose an ...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Noise Reduction by Projection Direction Dependent Diffusion for Low Dose Fan-beam X-ray Computed Tomography

We propose a novel method to reduce the noise in fan-beam computed tomography (CT) imaging. First, the inverse Radon transform is induced for a family of differential expression of projection function. Second, the diffusion partial differential equation (PDE) is generalized from image space to projection space in parallel-beam geometry. Third, the diffusion PDE is further induced from parallel-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 56 14  شماره 

صفحات  -

تاریخ انتشار 2011