The UF family of reference hybrid phantoms for computational radiation dosimetry.

نویسندگان

  • Choonsik Lee
  • Daniel Lodwick
  • Jorge Hurtado
  • Deanna Pafundi
  • Jonathan L Williams
  • Wesley E Bolch
چکیده

Computational human phantoms are computer models used to obtain dose distributions within the human body exposed to internal or external radiation sources. In addition, they are increasingly used to develop detector efficiencies for in vivo whole-body counters. Two classes of computational human phantoms have been widely utilized for dosimetry calculation: stylized and voxel phantoms that describe human anatomy through mathematical surface equations and 3D voxel matrices, respectively. Stylized phantoms are flexible in that changes to organ position and shape are possible given avoidance of region overlap, while voxel phantoms are typically fixed to a given patient anatomy, yet can be proportionally scaled to match individuals of larger or smaller stature, but of equivalent organ anatomy. Voxel phantoms provide much better anatomical realism as compared to stylized phantoms which are intrinsically limited by mathematical surface equations. To address the drawbacks of these phantoms, hybrid phantoms based on non-uniform rational B-spline (NURBS) surfaces have been introduced wherein anthropomorphic flexibility and anatomic realism are both preserved. Researchers at the University of Florida have introduced a series of hybrid phantoms representing the ICRP Publication 89 reference newborn, 15 year, and adult male and female. In this study, six additional phantoms are added to the UF family of hybrid phantoms-those of the reference 1 year, 5 year and 10 year child. Head and torso CT images of patients whose ages were close to the targeted ages were obtained under approved protocols. Major organs and tissues were segmented from these images using an image processing software, 3D-DOCTOR. NURBS and polygon mesh surfaces were then used to model individual organs and tissues after importing the segmented organ models to the 3D NURBS modeling software, Rhinoceros. The phantoms were matched to four reference datasets: (1) standard anthropometric data, (2) reference organ masses from ICRP Publication 89, (3) reference elemental compositions provided in ICRP 89 as well as ICRU Report 46, and (4) reference data on the alimentary tract organs given in ICRP Publications 89 and 100. Various adjustments and refinements to the organ systems of the previously described newborn, 15 year and adult phantoms are also presented. The UF series of hybrid phantoms retain the non-uniform scalability of stylized phantoms while maintaining the anatomical realism of patient-specific voxel phantoms with respect to organ shape, depth and inter-organ distance. While the final versions of these phantoms are in a voxelized format for radiation transport simulation, their primary format is given as NURBS and polygon mesh surfaces, thus permitting one to sculpt non-reference phantoms using the reference phantoms as an anatomic template.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hybrid Phantom Applications to Nuclear Medicine

Annually, many people are irradiated for diagnostic and therapeutic purposes. Assessment of radiation dose and its related risks to patients are important issues in radiation protection dosimetry. The complex mathematical calculations of the absorbed and effective doses are now done with computers. The calculations are performed with the help of anthropomorphic computational models of human bod...

متن کامل

Development of Iranian Adult Female Reference Phantom for Internal Dosimetry Calculations

Estimation of organ doses in diagnostic and therapeutic nuclear medicine procedures is an area of particular concern for radiation protection, in all over the world. The stylized computational phantoms have contributed significantly to radiation dosimetry in nuclear medicine; however, their simplified treatment of human anatomy is being criticized. Due to the fact that the ICRP adult reference ...

متن کامل

Development of Prototype Iranian male pelvic phantom for internal dosimetry

Introduction: Existing phantoms have been constructed based on Caucasian, non-Caucasian and race-specific datasets. According to previous studies made efforts to present Korean- specific phantoms and Chinese female phantom based on CVH dataset due to compare the resulting internal dosimetry with the Caucasian based data showed possible racial difference in human anatomy between ...

متن کامل

Developing the Adult Male ICRP Phantom and Evaluation the Absorbed Dose Received By Critical Organs in Head and Neck Region during the Radiotherapy of Eye Cancer

Introduction Accurate estimation of the absorbed dose in radiosensitive organs, located away from the target volume during radiotherapy, is one of the main reasons for the development of reference phantoms. The International Commission on Radiological Protection (ICRP) reference phantoms can provide a more realistic view of the human anatomy in comparison with the previously used mathematical p...

متن کامل

A CVH-based computational female pelvic phantom for radiation dosimetry simulation

Background: Accurate voxel phantom is needed for dosimetric simulation in radiation therapy for malignant tumors in female pelvic region. However, most of the existing voxel phantoms are constructed on the basis of Caucasian or non-Chinese population. Materials and Methods: A computational framework for constructing female pelvic voxel phantom for radiation dosimetry was performed base...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 55 2  شماره 

صفحات  -

تاریخ انتشار 2010