In vitro absorption of atmospheric carbon monoxide and hydrogen cyanide in undisturbed pooled blood.

نویسندگان

  • Tiffany M Thoren
  • Kristi S Thompson
  • Patrick S Cardona
  • Arvind K Chaturvedi
  • Dennis V Canfield
چکیده

Blood samples from aircraft accident victims are analyzed for carboxyhemoglobin (COHb) and cyanide ion (CN(-)). Such victims often suffer open wounds near the autopsy blood collection sites. Many aircraft crashes result in fires that fill the victim's atmosphere with smoke that is rich in carbon monoxide (CO) and hydrogen cyanide (HCN). It is important to determine whether pooled blood in those wounds may have absorbed these gases after death, which could lead one to erroneously conclude that the presence of COHb and CN(-) in blood was the result of breathing in these gases. A laboratory desiccator was used as a chamber to establish whether CO or HCN may be absorbed in undisturbed, pooled blood. COHb levels were 4.3-11.0% after exposure to CO (5,532, 8,298, 11,064, 22,129 and 33,193 ppm) for 30 and 60 min. Blood CN(-) concentrations (1.43-5.01 µg/mL) increased with exposure to HCN at 100 and 200 ppm, each at 15, 30, 45 and 60 min. The observed COHb increases do not exclude the possibility for higher COHb levels in blood exposed to highly CO-rich atmospheres, but there is a strong potential for CN(-) levels to increase by the absorption of atmospheric HCN. Thus, postmortem COHb and CN(-) levels should be carefully interpreted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ACP Broadsheet No 142: November 1993. Measurement of carbon monoxide and cyanide in blood.

Introduction Carbon monoxide and hydrogen cyanide are often found in fire atmospheres. These gases can incapacitate rapidly and thus render the victim unable to escape from the fire. High concentrations of carbon monoxide and hydrogen cyanide found in the blood of fire victims indicate a degree of survival in the toxic fire atmosphere. Concentrations may be sufficiently high in the blood to att...

متن کامل

Infrared Spectroscopy on Smoke Produced by Cauterization of Animal Tissue

In view of in vivo surgical smoke studies a difference-frequency-generation (DFG) laser spectrometer (spectral range 2900-3144 cm(-1)) and a Fourier-transform infrared (FTIR) spectrometer were employed for infrared absorption spectroscopy. The chemical composition of smoke produced in vitro with an electroknife by cauterization of different animal tissues in different atmospheres was investigat...

متن کامل

End-tidal Carbon Dioxide Measurements in Unintentional Non-Fire-Related Carbon Monoxide Poisoning

Background: Poisoning with carbon monoxide occurs occasionally worldwide, and the gold diagnostic standard is to measure carboxyhemoglobin level in the blood. This study investigated the correlation between carboxyhemoglobin and the end-tidal carbon dioxide levels in 50 patients with carbon monoxide poisoning. Methods: We recruited 50 volunteer patients who had been admitted to the Emergency S...

متن کامل

Hydrogen Cyanide Production During Reduction of Nitric Oxide over Platinum Catalysts: Transient Effects.

The formation of hydrogen cyanide during the catalytic reduction of nitric oxide (NO) with carbon monoxide and hydrogen was studied with a bench-scale flow reactor. The previously reported inhibition by sulfur dioxide of the formation of hydrogen cyanide was found to be counteracted by transient admission of oxygen to the catalyst. These results are discussed in the context of the control of au...

متن کامل

Preparation of Carbon Molecular Sieves from Pistachio Shell and Walnut Shell for Kinetic Separation of Carbon Monoxide, Hydrogen, and Methane

In this study, two Carbon Molecular Sieves using Pistachio shell (CMS P) and Walnut shell (CMS W) were prepared by a chemical vapor deposition method and used for pressure swing adsorption and separation of CO/H2 and CO/CH4. Adsorption isotherms of gases obtained for both CMS’s. The Dubinin-Radushkevich isotherm model was used for comparing pore volum...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 37 4  شماره 

صفحات  -

تاریخ انتشار 2013