Does breast size affect the scatter dose to the ipsilateral lung, heart, or contralateral breast in primary breast irradiation using intensity-modulated radiation therapy (IMRT)?

نویسندگان

  • Ajay K Bhatnagar
  • Dwight E Heron
  • Melvin Deutsch
  • Edward Brandner
  • Andrew Wu
  • Shalom Kalnicki
چکیده

PURPOSE To evaluate the relationship between the primary breast volume and dose received by the ipsilateral lung, heart (for left-breast cancers), and contralateral breast during primary breast irradiation using intensity-modulated radiation therapy (IMRT). METHODS AND MATERIALS Sixty-five patients with breast carcinoma were treated using 6-MV photons with IMRT technique using the Eclipse Planning System following breast conserving surgery. All patients had a treatment planning CT scan. The primary breast, ipsilateral lung, and heart were contoured on the axial CT slices. The primary breast volume was calculated using the Eclipse Planning System. The mean ipsilateral lung and heart doses were obtained from the dose-volume histogram. The contralateral breast dose was measured using paired thermoluminescent dosimeters (TLDs) placed on the patient's contralateral breast, 4 cm from the center of the medial border of the primary breast irradiation field. RESULTS The mean dose delivered with photons to the primary breast for all patients was 49.97 Gy. The mean volume of the primary irradiated breast was 1167.9 cc. As a percentage, the mean ipsilateral lung, heart, and contralateral breast doses were 11.2%, 6.1%, and 7.2%, respectively. The primary breast volume positively correlated with the contralateral breast dose (P < 0.0005). There was no significant correlation between the breast volume and the ipsilateral lung or heart dose (P = 0.463 and 0.943, respectively). CONCLUSION This study suggests that the primary breast size significantly affects the scatter dose to the contralateral breast but not the ipsilateral lung or heart dose when using IMRT for breast irradiation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intensity modulated radiation therapy (IMRT) technique for left breast cancer by different numbers of beam fields

Background: Intensity Modulated Radiotherapy (IMRT) can improve radiotherapy (RT) results by improving healthy tissue sparing. Additionally, IMRT provides more consistent dose deliveries and suppresses secondary tumor formation. RT is a principal treatment in breast cancer (BC). Aim: To evaluate the outcome of the Radiotherapy Plans (RTP) that use IMRT technique to left breast and other organs,...

متن کامل

Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions

Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...

متن کامل

Comparison of dosimetric radiotherapy of whole left- breast cancer using conventional tangential wedge-based techniques (CTT) and three intensity modulation techniques (IMRT)

Introduction: Whole breast radiotherapy after breast-conserving surgery decrease the risk of local recurrence. this study investigates the dosimetric aspects of intensity modulated radiotherapy (IMRT) compared to conventional tangential wedge-based beams techniques (CTT) of the whole breast in early stages breast cancer patients.   Materials and Methods: Co...

متن کامل

Optimization of tangential fields arrangement in the breast cancer 3D conformal radiation therapy

Introduction: The incidence of breast cancer increases with the rate of 1-2% at the world. Radiation therapy is one of the available choices for breast cancer treatment. The single isocentre half-beam block technique is considered as a standard technique to avoid hot and cold spots within the PTV. The major advantage of half beam technique is that the both contralateral breast...

متن کامل

Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were cr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of clinical oncology

دوره 29 1  شماره 

صفحات  -

تاریخ انتشار 2006