Optimal Cardiac Resynchronization Therapy Pacing Rate in Non-Ischemic Heart Failure Patients: A Randomized Crossover Pilot Trial

نویسندگان

  • Adam Ali Ghotbi
  • Mikael Sander
  • Lars Køber
  • Berit Th. Philbert
  • Finn Gustafsson
  • Christoffer Hagemann
  • Andreas Kjær
  • Peter K. Jacobsen
  • Yoshihiro Fukumoto
چکیده

BACKGROUND The optimal pacing rate during cardiac resynchronization therapy (CRT) is unknown. Therefore, we investigated the impact of changing basal pacing frequencies on autonomic nerve function, cardiopulmonary exercise capacity and self-perceived quality of life (QoL). METHODS Twelve CRT patients with non-ischemic heart failure (NYHA class II-III) were enrolled in a randomized, double-blind, crossover trial, in which the basal pacing rate was set at DDD-60 and DDD-80 for 3 months (DDD-R for 2 patients). At baseline, 3 months and 6 months, we assessed sympathetic nerve activity by microneurography (MSNA), peak oxygen consumption (pVO2), N-terminal pro-brain natriuretic peptide (p-NT-proBNP), echocardiography and QoL. RESULTS DDD-80 pacing for 3 months increased the mean heart rate from 77.3 to 86.1 (p = 0.001) and reduced sympathetic activity compared to DDD-60 (51±14 bursts/100 cardiac cycles vs. 64±14 bursts/100 cardiac cycles, p<0.05). The mean pVO2 increased non-significantly from 15.6±6 mL/min/kg during DDD-60 to 16.7±6 mL/min/kg during DDD-80, and p-NT-proBNP remained unchanged. The QoL score indicated that DDD-60 was better tolerated. CONCLUSION In CRT patients with non-ischemic heart failure, 3 months of DDD-80 pacing decreased sympathetic outflow (burst incidence only) compared to DDD-60 pacing. However, Qol scores were better during the lower pacing rate. Further and larger scale investigations are indicated. TRIAL REGISTRATION ClinicalTrials.gov NCT02258061.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the rhythm control treatment strategy versus the rate control strategy in patients with permanent or long-standing persistent atrial fibrillation and heart failure treated with cardiac resynchronization therapy - a pilot study of Cardiac Resynchronization in Atrial Fibrillation Trial (Pilot-CRAfT): study protocol for a randomized controlled trial

BACKGROUND The only subgroups of patients with heart failure and atrial fibrillation in which the efficacy of cardiac resynchronization therapy has been scientifically proven are patients with indications for right ventricular pacing and patients after atrioventricular junction ablation. However it is unlikely that atrioventricular junction ablation would be a standard procedure in the majority...

متن کامل

Reduced ventricular volumes and improved systolic function with cardiac resynchronization therapy: a randomized trial comparing simultaneous biventricular pacing, sequential biventricular pacing, and left ventricular pacing.

BACKGROUND Cardiac resynchronization therapy has emerged as an important therapy for advanced systolic heart failure. Among available cardiac resynchronization therapy pacing modes that restore ventricular synchrony, it is uncertain whether simultaneous biventricular (BiV), sequential BiV, or left ventricular (LV) pacing is superior. The Device Evaluation of CONTAK RENEWAL 2 and EASYTRAK 2: Ass...

متن کامل

Rate responsive pacing using cardiac resynchronization therapy in patients with chronotropic incompetence and chronic heart failure.

AIMS Chronotropic incompetence (CI) is a common finding in patients with advanced chronic heart failure (CHF) and is associated with a worse functional capacity. Whether rate responsive pacing with cardiac resynchronization therapy (CRT) would acutely improve exercise performance in patients with advanced CHF and severe CI (<70% age-predicted maximum heart rate) is unknown. METHODS AND RESULT...

متن کامل

[Antitachycardia pacing efficacy significantly improves with cardiac resynchronization therapy].

INTRODUCTION AND OBJECTIVES The effect of cardiac resynchronization therapy on antitachycardia pacing still has to be determined. PATIENTS AND METHOD A total of 490 heart failure patients with an indication for an implantable cardioverter-defibrillator participated in the VENTAK CHF/CONTAK CD study, a single-blind, randomized, placebo-controlled study. We compared antitachycardia pacing effic...

متن کامل

A comparison of cardiac resynchronization by sequential biventricular pacing and left ventricular pacing to simultaneous biventricular pacing: rationale and design of the DECREASE-HF clinical trial.

BACKGROUND The first generation of cardiac resynchronization therapy (CRT) devices approved for the treatment of heart failure used simultaneous biventricular (BiV) pacing to achieve ventricular resynchronization. Left ventricular pacing alone and sequential BiV pacing also show promise as alternative ways to deliver CRT, but have not been studied together in a large randomized trial. METHODS...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015