Field evaluation of the ICT malaria P.f/P.v immunochromatographic test for detection of Plasmodium falciparum and Plasmodium vivax in patients with a presumptive clinical diagnosis of malaria in eastern Indonesia.
نویسندگان
چکیده
In areas such as eastern Indonesia where both Plasmodium falciparum and Plasmodium vivax occur, rapid antigen detection tests for malaria need to be able to detect both species. We evaluated the new combined P. falciparum-P. vivax immunochromatographic test (ICT Malaria P.f/P.v.) in Radamata Primary Health Centre, Sumba, Indonesia, from February to May 1998 with 560 symptomatic adults and children with a presumptive clinical diagnosis of malaria. Blinded microscopy was used as the "gold standard," with all discordant and 20% of concordant results cross-checked blindly. Only 50% of those with a presumptive clinical diagnosis of malaria were parasitemic. The ICT Malaria P.f/P.v immunochromatographic test was sensitive (95. 5%) and specific (89.8%) for the diagnosis of falciparum malaria, with a positive predictive value (PPV) and a negative predictive value (NPV) of 88.1 and 96.2%, respectively. HRP2 and panmalarial antigen line intensities were associated with parasitemia density for both species. Although the specificity and NPV for the diagnosis of vivax malaria were 94.8 and 98.2%, respectively, the overall sensitivity (75%) and PPV (50%) for the diagnosis of vivax malaria were less than the desirable levels. The sensitivity for the diagnosis of P. vivax malaria was 96% with parasitemias of >500/microl but only 29% with parasitemias of <500/microl. Nevertheless, compared with the test with HRP2 alone, use of the combined antigen detection test would reduce the rate of undertreatment from 14.7 to 3.6% for microscopy-positive patients, and this would be at the expense of only a modest increase in the rate of overtreatment of microscopy-negative patients from 7.1 to 15. 4%. Cost remains a major obstacle to widespread use in areas of endemicity.
منابع مشابه
Comparison of Rapid Immunochromatographic Assays (ict Malaria P.f. /p.v. Test and Optimal Test) with Microscopy for Detection of Malaria Parasites
This study was conducted to compare the ability of developed immunochromatographic assays, ICT malaria P.f./P.v. test and OptiMAL test with standard microscopy for the diagnosis of malaria parasites. Blood samples were obtained from 150 patients clinically suspected of having malaria. A total of 59 samples (39.3%) were positive by blood films while 64 (42.7%) were positive by ICT p.f./p.v. and ...
متن کاملRapid diagnostic devices for malaria: field evaluation of a new prototype immunochromatographic assay for the detection of Plasmodium falciparum and non-falciparum Plasmodium.
The NOW ICT Malaria P.f./P.v. for Whole Blood (Binax, Inc., Portland, ME) is a new malaria rapid diagnostic device that represents a technical advance over previous assays, such as ICT Malaria P.f./P.v. and ICT Malaria P.f.. We evaluated this device in March 2001 in symptomatic patients at malaria clinics in Maesod, Thailand. Microscopic examination of Giemsa-stained blood smears was the refere...
متن کاملEvaluation of the ICT malaria P.f/P.v and the OptiMal rapid diagnostic tests for malaria in febrile returned travellers.
Rapid diagnostic tests (RDTs) are less reliant on expert microscopy and have the potential to reduce errors in malaria diagnosis but have not been extensively evaluated in nonimmune persons or in countries where infection is not endemic. We evaluated the ICT P.f/P.v (ICT-Amrad, Sydney, Australia) and OptiMal (Flow Inc., Portland, Oreg.) assays prospectively for the diagnosis of malaria in 158 s...
متن کاملMolecular Evidence on Changing Pattern of Mixed Plasmodium falciparum and P. vivax Infections during Year-Round Transmission of Malaria in Chahbahar, Iran
Mixed malaria infections, Plasmodium falciparum and P. vivax, are suspected to occur at a greater frequency than is detected by conventional light microscopy. In order to determine the year round pattern of transmission and the frequency of mixed infections in malaria endemic area, we carried out a prospective comparison of diagnosis by conventional light microscopy and nested PCR in Chahbahar ...
متن کاملValidation of microscopic diagnosis of malaria in field laboratories of malarious areas of Iran by Nested PCR
Introduction: Examination of Geimsa stained blood smears is the main method of malaria diagnosis in our country, however, accuracy of results is largely depended on the skill and laboratory conditions. This study was designed and carried out to assess the current situation and to determine the effectiveness and quality improvement of malaria diagnosis program. Methods: In this analytical s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 37 8 شماره
صفحات -
تاریخ انتشار 1999