The accuracy and response characteristics of a simplified ear oximeter.

نویسندگان

  • K R Chapman
  • A D'Urzo
  • A S Rebuck
چکیده

We evaluated the accuracy and speed of response of a newly available, lightweight, and relatively inexpensive ear oximeter (Biox II oximeter). The instrument was compared with another oximeter (Hewlett-Packard 47201A) under conditions of both steadily maintained and progressively increasing hypoxia induced in normal subjects by rebreathing. The new oximeter (Biox II), which can be operated in either a "normal" or "fast" response mode, as selected by a switch on the front panel, was evaluated in its "normal" mode during steady-state hypoxic conditions and in both "normal" and "fast" modes during progressive hypoxic conditions. The other oximeter (HP 47201A) was operated in its factory preset "normal" mode for all measurements. During steady-state hypoxia the relationship between oximetric arterial oxygen saturation (SaO2) readings (y) and spectrophotometrically measured SaO2 in samples of arterial blood (x) when SaO2 exceeded 65 percent was as follows: for the new oximeter (Biox), y = 0.95x + 3.25 (r = 0.96); and for the other oximeter (HP 47201A), y = 1.03x - 2.31 (r = 0.94). Neither of these relationships differed significantly from the line of identity. During trials of progressive isocapnic hypoxia induced acutely in ten normal subjects, SaO2 was measured continuously by both oximeters. With the new oximeter (Biox) operated in the "normal" mode, the relationship between values for SaO2 from it (y) and the other oximeter (Hewlett-Packard) (x) was y = 0.85x + 12.91 (r = 0.93). When the new oximeter (Biox) was switched to its "fast" response mode, the relationship more closely approximated the line of identity such that y = 1.05x - 5.95 (r = 0.98). The response of the new oximeter (Biox II) to an in vitro step change in saturation followed a complex nonexponential function characterized by small initial changes in output signal with the greatest changes in output occurring during the latter portion of the response period. The 50 percent response times of the new oximeter (Biox II) were 5.65 seconds and 2.86 seconds in the "normal" and "fast" modes, respectively, by contrast to the 50 percent response time of 2.87 seconds for the other oximeter (H-P 47201A). We conclude that the new oximeter (Biox II) demonstrated accuracy comparable to a more complex and expensive oximeter and had response characteristics that may be useful in clinical and laboratory settings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

a Simplified Model of Distributed Parameter Systems

A generalized simplified model for describing the dynamic behavior of distributed parameter systems is proposed. The various specific characteristics of gain and phase angle of distributed parameter systems are investigated from frequency response formulation and complex plane representation of the proposed simplified model. The complex plane investigation renders some important inequality cons...

متن کامل

The Use of the Ear Oximeter for Measurement of the Cardiac Output During Walking Exercise in Human Subjects ‡

For the study of walking exercise in human subjects, an accurate method for measurement of the cardiac output is needed which can be applied repeatedly and with minimal discomfort to the subject. Continuous recording of dye-dilution curves by means of an ear oximeter has been used previously,"'9'10 for estimating the cardiac output at rest, and requires only venipuncture. However, the accuracy ...

متن کامل

Through the endoscope balloon dilatation of benign gastric outlet obstruction.

This study was supported by the Asthma Foundation of Western Australia and the TVW Telethon Foundation. Lee DA, W(inslow NR, Speight ANP, Hev EN. IPrevalence and spectrum of asthma in childhood. BrMed.7 1983;286:1258-60. 2 McFadden ER, Lvons HA. Arterial-blood gas tension in asthma. N' Et-ngI7 Mtled 1968;278: 1027-32. 3 Burki NK, Albert RK. Noninvasive monitoring of arterial blood gases: a repo...

متن کامل

Frequency Domain Model Simplification of Cumulative Mass Fraction in CMSMPR Crystallizer

In this contribution, linearized dynamic model of Cumulative Mass Fraction (CMF) of Potassium Nitrate-Water Seeded Continues Mixed Suspension Mixed Product Removal (CMSMPR) crystallizer is approximated by a simplified model in frequency domain. Frequency domain model simplification is performed heuristically using the frequency response of the derived linearized models data. However, the CM...

متن کامل

Volume-Filling Effects on Sloshing Frequency in Simplified and Explicit Dynamic Finite Element Models of Tank Wagons During Braking and Turning

Numerical analysis of fluid sloshing in tank wagons is amongst essential research ideas that are focused by railway engineers. The free surface of fluid becomes unstable and turns into a dynamic complex non-linear problem for fluid-structure interaction (FSI). In this paper, initially, the dynamic response of the tank, including lateral force analysis and pressure distribution during braking, i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 83 6  شماره 

صفحات  -

تاریخ انتشار 1983