Comparison of Corneal and Anterior Chamber Parameters following Myopic laser in situ keratomileusis and photorefractive keratectomy by Pentacam as A New Imaging Technique

نویسندگان

  • Mohammad Ali Zare
  • Mohammadreza Fallah Tafti
  • Ahmad Kheirkhah
چکیده

Purpose: To compare changes in posterior corneal elevation, anterior chamber depth (ACD), anterior chamber volume (ACV) and corneal volume (CV) after laser in situ keratomileusis (LASIK ) and photorefractive keratectomy (PRK) for low to moderate myopia by pentacam imaging Methods: In this prospective comparative case series, 105 consecutive myopic eyes randomly scheduled for LASIK (n=59) or PRK (n=46) in Farabi Eye Hospital, underwent pentacam imaging. Posterior corneal elevation, ACD, ACV and CV changes before and 6 months after operation were evaluated. Results: Mean posterior displacement was 4.55±4.12 μm (range: -4 to +18 μm) and 3.9±4.5 μm (-4 to +21 μm) in LASIK and PRK treated eyes, respectively (P>0.05). The ACV, ACD and CV were decreased in both groups but the reduction of these parameters pre and postoperatively in each group and between two groups was not statistically significant (P>0.05). Conclusion: There was no significant difference in posterior corneal displacement, ACD, ACV and CV between LASIK and PRK treated eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Changes in the posterior cornea after laser in situ keratomileusis and photorefractive keratectomy.

PURPOSE To study the changes in posterior corneal elevation after laser in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK) using Scheimpflug topography with the Pentacam anterior segment imaging system (Oculus, Inc.). SETTING Department of Ophthalmology, Albany Medical Center, and a private clinical practice, Albany, New York, USA. METHODS In this prospective study, 121 co...

متن کامل

Therapeutic alloplastic laser in situ keratomileusis for myopia.

BACKGROUND A new technique, therapeutic alloplastic laser in situ keratomileusis to correct high myopia, is introduced. METHODS Therapeutic alloplastic laser in situ keratomileusis consists of neutral homoplastic epikeratoplasty combined with superficial keratectomy performed with an excimer laser and/or a microkeratome. Indications for the technique are: myopia over 20 diopters (D), eyes wit...

متن کامل

Comparison between Pentacam HR and Orbscan II after Hyperopic Photorefractive Keratectomy

PURPOSE The aim of this study was to determine the agreement between Pentacam HR (Scheimpflug imaging, Oculus) and Orbscan II (scanning slit topography, Bausch and Lomb) in measuring corneal parameters after photorefractive keratectomy (PRK) for hyperopia. METHODS In this prospective cross-sectional study, 38 hyperopic eyes undergoing PRK were examined before refractive surgery and 8 to 10 mo...

متن کامل

تغییرات برآمدگی سطح خلفی قرنیه پس از جراحی فتورفرکتیوکراتکتومی

  Background : Posterior corneal elevation changes are keys to early diagnosis of corneal ectasia after keratorefractive surgery, so it is important to use an accurate method for measuring posterior corneal elevation. The purpose of this study is investigating posterior corneal elevation changes with Pentacam(HR) on patients underwent photorefractive keratectomy.   Methods: In this clinical tri...

متن کامل

Calculations of actual corneal astigmatism using total corneal refractive power before and after myopic keratorefractive surgery

PURPOSE To calculate actual corneal astigmatism using the total corneal refractive astigmatism for the 4-mm apex zone of the Pentacam (TCRP4astig) and keratometric astigmatism (Kastig) before and after photorefractive keratectomy or laser in situ keratomileusis. METHODS Uncomplicated 56 eyes after more than 6 months from the surgery were recruited by chart review. Various corneal astigmatisms...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017