Multibeam field emission x-ray system with half-scan reconstruction algorithm.

نویسندگان

  • Yang Lu
  • Hengyong Yu
  • Guohua Cao
  • Jun Zhao
  • Ge Wang
  • Otto Zhou
چکیده

PURPOSE In this article, the authors propose a multibeam field emission x-ray (MBFEX) system along with a half-scan fan-beam reconstruction algorithm. METHODS The proposed system consists of a linear CNT-based MBFEX source array, a single large area detector that is divided into same number of segments as the number of x-ray beams, a multihole collimator that aligns each beam with a corresponding detector segment, and a sample rotation stage. The collimator is placed between the source and the object to restrict the x-ray radiations through the target object only. In this design, all the x-ray beams are activated simultaneously to provide multiple projection views of the object. The detector is virtually segmented and synchronized with the x-ray exposure and the physiological signals when gating is involved. The transmitted x-ray intensity from each beam is collected by the corresponding segment on the detector. After each exposure, the object is rotated by a step angle until sufficient data set is collected. The half-scan reconstruction formula for MBFEX system is derived from the conventional filtered backprojection algorithm. To demonstrate the advantages of the system and method in reducing motion artifacts, the authors performed simulations with both standard and dynamic Shepp-Logan phantoms. RESULTS The numerical results indicate that the proposed multibeam system and the associated half-scan algorithm can effectively reduce the scanning time and improve the image quality for a time-varying object. CONCLUSIONS The MBFEX technique offers an opportunity for the innovation of multisource imaging system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Half-scan cone-beam CT fluoroscopy with multiple x-ray sources.

To develop volumetric micro-CT fluoroscopy for small animal imaging, we have proposed a cone-beam system with multiple x-ray sources. In this paper, we extend Parker's single-source half-scan weighting scheme to the case of an odd number of x-ray sources that are equiangularly distributed, and apply it for half-scan Feldkamp-type reconstruction in this unique geometry. In the numerical simulati...

متن کامل

3D Analytic Cone-Beam Reconstruction for Multiaxial CT Acquisitions

A conventional 3rd generation Computed Tomography (CT) system with a single circular source trajectory is limited in terms of longitudinal scan coverage since extending the scan coverage beyond 40 mm results in significant cone-beam artifacts. A multiaxial CT acquisition is achieved by combining multiple sequential 3rd generation axial scans or by performing a single axial multisource CT scan w...

متن کامل

Accelerated Optimization Algorithms for Statistical 3d X-ray Computed Tomography Image Reconstruction

ACCELERATED OPTIMIZATION ALGORITHMS FOR STATISTICAL 3D X-RAY COMPUTED TOMOGRAPHY IMAGE RECONSTRUCTION by Donghwan Kim Chair: Jeffrey A. Fessler X-ray computed tomography (CT) has been widely celebrated for its ability to visualize the anatomical information of patients, but has been criticized for high radiation exposure. Statistical image reconstruction algorithms in X-ray CT can provide impro...

متن کامل

Image Reconstruction for X-ray Computed Tomography in Security Screening Applications

Kisner, Sherman J. Ph.D., Purdue University, December 2013. Image Reconstruction for X-ray Computed Tomography in Security Screening Applications. Major Professor: Charles A. Bouman. X-ray tomographic systems have increasingly widespread use in security screening applications. For example, most major airports now utilize X-ray CT systems for efficient screening of baggage and cargo. While decad...

متن کامل

Exact Reconstruction From Uniformly Attenuated Helical Cone-Beam Projections in SPECT

In recent years the development of cone-beam reconstruction algorithms has been an active research area in x-ray computed tomography (CT), and significant progress has been made in the advancement of algorithms. Theoretically exact and computationally efficient analytical algorithms can be found in the literature. However, in single photon emission computed tomography (SPECT), published cone-be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 37 7  شماره 

صفحات  -

تاریخ انتشار 2010