Is the transvenous extraction of cardioverter-defibrillator leads more hazardous than that of pacemaker leads?

نویسندگان

  • Barbara Małecka
  • Andrzej Kutarski
  • Marcin Grabowski
چکیده

BACKGROUND Leads used for low-voltage and high-voltage therapy delivered by implantable cardioverter-defibrillators (ICD) differ from low-voltage pacemaker (PM) leads in their diameter and complexity of structure. Although there are reports showing that the extraction of ICD leads may be hazardous, due to firm adhesions to the vascular and chamber walls of high-voltage therapy coils, clinical evidence suggests that such procedures are safe. AIM To compare the efficacy and safety of transvenous extraction of ICD and PM leads in patients enrolled in a single tertiary centre. METHODS We compared the results of lead extraction procedures in 345 patients with PM and in 79 patients submitted for the lead removal including at least one ICD lead. We analysed ingrown leads i.e. over 12 month-old PM leads and over 6 month-old ICD leads, which were removed using Cook's device. RESULTS Patients in the two groups differed significantly in age and gender. The ICD systems were significantly younger, less complex (fewer leads per patient) and presented higher efficacy of extraction and fewer technical difficulties. The number of major complications was similar to the encountered during extraction of PM leads. However, minor complications were significantly more frequent in the ICD group. CONCLUSIONS 1. Extraction of ICD and PM leads is associated with a similar risk for developing major complications, however minor complications are more often during extraction of ICD leads. 2. A larger number of double coil leads may be the cause of complications despite a shorter time period elapsing from ICD implantation. 3. A probable cause of complications during ICD lead extraction is the pronounced growth of the connective tissue around the coils. However, further studies are required to clarify this phenomenon. 4. The success rate of ICD leads extraction using our own surgical technique is similar to that reported by other investigators using laser systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Broken leads with proximal endings in the cardiovascular system: serious consequences and extraction difficulties.

BACKGROUND Retrospective analysis of effectiveness, technical problems, and complications of transvenous extraction of leads with the free endings migrated to the cardiovascular system (CVS). METHODS A 5-year-old database of transvenous lead extraction (TLE) procedures comprising 906 patients with 1563 leads being removed was analyzed. TLE procedures of leads migrated in the CVS were compared...

متن کامل

Managing cross talk between a subcutaneous implantable cardioverter-defibrillator and a dual-chamber unipolar pacemaker system

Introduction In cases of patients who have contraindications to transvenous pacing leads but still require pacing, surgically placed epicardial pacing leads are often used. If such a patient warranted implantable cardioverter-defibrillator (ICD), a subcutaneous ICD (S-ICD) system would be ideal from the standpoint of avoidance of transvenous leads, but devicedevice interaction with the epicardi...

متن کامل

Pacemaker lead endocarditis with hiccups (Kalayci)

Background: Lead-related infections that might develop after pacemaker implantation associated with high mortality and morbidity rates are challenging to manage and pose high-cost. Patients with lead-related infections usually present with fever, chills and fatigue and the treatment can be challenging unless the implant system is extracted. Case presentation: A 66-year old male patient who und...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Kardiologia polska

دوره 68 8  شماره 

صفحات  -

تاریخ انتشار 2010