Using the 320-Multidetector Computed Tomography scanner for four-dimensional functional assessment of the elbow joint.

نویسندگان

  • Yin Peng Goh
  • Kenneth K Lau
چکیده

As described in this case report, the use of the 320-Multidetector Computed Tomography scanner (Aquilion One, Toshiba Medical Systems, Japan) to produce continuous 3-dimensional images in real time, over a distance of 16 cm in the z-axis, proved to aid in the diagnosis of a patient's restrictive elbow joint. This state-of-the-art scanner allows fast and noninvasive dynamic-kinematic functional evaluation of the elbow joint in vivo. It will also be applicable to kinematic studies of other joints.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional reconstruction of New Zealand rabbit antebrachium by multidetector computed tomography

The aim of this study was to reveal biometric peculiarities of New Zealand white rabbit antebrachium (radius and ulna) by means of three-dimensional (3D) reconstruction of multidetector computed tomography (MDCT) images. Under general anesthesia, the antebrachiums of a total of sixteen rabbits of both sexes were scanned with a general diagnostic MDCT. Biometric measurements of the reconstructed...

متن کامل

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

Absorbed Radiation Dose in Radiosensitive Organs Using 64- and 320-Row Multidetector Computed Tomography: A Comparative Study

Aim. To determine absorbed radiation dose (ARD) in radiosensitive organs during prospective and full phase dose modulation using ECG-gated MDCTA scanner under 64- and 320-row detector modes. Methods. Female phantom was used to measure organ radiation dose. Five DP-3 radiation detectors were used to measure ARD to lungs, breast, and thyroid using the Aquilion ONE scanner in 64- and 320-row modes...

متن کامل

Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners

Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...

متن کامل

Primary tracheobronchial amyloidosis associated with tracheobronchomegaly evaluated by novel four‐dimensional functional CT

Amyloid is a heterogeneous family of extracellular proteinaceous deposits characterized by apple-green birefringence on polarized light microscopy. There are rare case reports of these extracellular deposits accumulating in the upper and central airways. Progressive infiltration may impair glottic and airway function with some cases requiring intervention to improve flow. Bronchoscopy and lung ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of orthopedics

دوره 41 2  شماره 

صفحات  -

تاریخ انتشار 2012