Validity and reliability of Omron pedometers for prescribed and self-paced walking.

نویسندگان

  • Elizabeth A Holbrook
  • Tiago V Barreira
  • Minsoo Kang
چکیده

PURPOSE The purpose of this study was to examine the validity and reliability evidence for the Omron Healthcare HJ-151 and HJ-720ITC pedometers for prescribed and self-paced walking. METHODS A total of 47 adults (24 males, 23 females; age = 24 +/- 4.4 yr.; body mass index = 25.7 +/- 4.2 kg x m(-2)) participated in this study. Under prescribed walking conditions, 34 participants completed three randomized 100-m walking trials through a range of scripted walking speeds (slow, moderate, and very brisk) for each pedometer model. Under self-paced walking conditions, 31 participants completed one 1-mile walk on a standardized course for each model. HJ-151 pedometers were chosen at random from a pool of 54 devices and were worn along the waistband at the right hip, the left hip, and the midback, whereas HJ-720ITC pedometers were chosen from a pool of 24 devices and incorporated right pocket, left pocket, and backpack positions in addition to the three waist-mounted sites. Absolute percent error (APE) scores were calculated to examine pedometer accuracy between actual steps (a criterion measure) and pedometer-determined steps. Coefficient of variation (CoV) was computed to describe interdevice reliability. RESULTS With the exception of the HJ-720ITC at the backpack position in the prescribed walking setting (mean APE = 3.4%), the HJ-151 and the HJ-720ITC accurately reported step counts under prescribed and self-paced conditions (all APE values <3.0%). Moreover, interdevice reliability evidence was established for the HJ-151 and the HJ-720ITC under prescribed and self-paced conditions (all CoV values <2.1%). CONCLUSIONS The Omron HJ-151 and HJ-720ITC pedometers demonstrated validity and reliability at various mounting positions under prescribed and self-paced walking conditions with both healthy and overweight adults.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validity and reliability of the Omron HJ-303 tri-axial accelerometer-based pedometer.

BACKGROUND This study compared the validity of a new Omron HJ-303 piezoelectric pedometer and 2 other pedometers (Sportline Traq and Yamax SW200). METHODS To examine the effect of speed, 60 subjects walked on a treadmill at 2, 3, and 4 mph. Twenty subjects also ran at 6, 7, and 8 mph. To test lifestyle activities, 60 subjects performed front-back-side-side stepping, elliptical machine and sta...

متن کامل

The validity and reliability of a novel activity monitor as a measure of walking.

BACKGROUND The accurate measurement of physical activity is crucial to understanding the relationship between physical activity and disease prevention and treatment. OBJECTIVE The primary purpose of this study was to investigate the validity and reliability of the activPAL physical activity monitor in measuring step number and cadence. METHODS The ability of the activPAL monitor to measure ...

متن کامل

Invariance of wearing location of Omron-BI pedometers: a validation study.

BACKGROUND The purpose of this study was to investigate the validity and reliability evidences of the Omron BI pedometer, which could count steps taken even when worn at different locations on the body. METHODS Forty (20 males and 20 females) adults were recruited to walk wearing 5 sets, 1 set at a time, of 10 BI pedometers during testing, 1 each at 10 different locations. For comparison, the...

متن کامل

The Accuracy of Pedometers in Measuring Walking Steps on a Treadmill in College Students

Pedometers are a popular way for people to track if they have reached the recommended 10,000 daily steps. Therefore, the purpose of this study was to determine the accuracy of four brands of pedometers at measuring steps, and to determine if a relationship exists between pedometer cost and accuracy. The hypothesis was that the more expensive brands of pedometers (the Fitbit Charge™ and Omron HJ...

متن کامل

The reliability and validity of a research-grade pedometer for children and adolescents with cerebral palsy.

AIM The aim of this study was to determine the reliability, validity, and optimal placement of pedometers in children with cerebral palsy (CP) who ambulate without aids. METHOD Seventeen participants aged 7 to 17 years with CP (eight males, nine females; mean age 12y 4mo; SD 3y 2mo), who could ambulate without aids, wore four New Lifestyles pedometers (NL-1000) on an elasticized waist belt. F...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medicine and science in sports and exercise

دوره 41 3  شماره 

صفحات  -

تاریخ انتشار 2009