Automated peritoneal dialysis: a Spanish multicentre study.

نویسندگان

  • A M Rodríguez
  • N V Díaz
  • L P Cubillo
  • J T Plana
  • M A Riscos
  • R M Delgado
  • C M Herrera
  • E A Ribes
  • F T Molina
  • M M Heras
  • A T González
  • C G Cantón
  • A R Fernández
  • E B Laborda
  • M N Zurita
  • F F Girón
  • P S Santana
چکیده

BACKGROUND A prospective sequential study on continuous ambulatory peritoneal dialysis (CAPD) and three techniques of automated peritoneal dialysis (APD) was conducted to assess peritoneal clearances, the influence of peritoneal permeability on nocturnal APD clearances and the suitability of the peritoneal equilibration test (PET) for predicting clearances on APD. METHODS After performing a PET, a series of clinical, biochemical and dialysis adequacy markers were evaluated after 2 months on CAPD, continuous cycling peritoneal dialysis (CCPD) and tidal volume peritoneal dialysis (TPD) with 50% and 25% tidal volumes. Forty five patients participated and 33 completed the study. RESULTS Serum urea and creatinine decreased significantly whereas haemoglobin and glucose increased. Mean peritoneal urea clearance (1/week) was 55.40+/-8.76 on CAPD, 74.82+/-12.62 on CCPD, 69.20+/-14.63 on TPD (tidal 50%) and 66.89+/-13.23 on TPD (tidal 25%); mean creatinine clearance (1/week/1.73 m2) was 42.80 +/- 9.95, 52.19 +/- 11.11, 51.31 +/- 13.3 and 49.17 +/- 11.83, respectively. Both clearances were significantly lower on CAPD than on APD (P<0.001). CCPD was the automated technique that provided the best nocturnal urea clearance (P<0.01). Nocturnal creatinine clearance did not show significant differences between CCPD and TPD (tidal 50%), being better with both techniques than with TPD (tidal 25%). There were statistically significant differences between nocturnal dialysate to plasma (D/P) ratios and those corresponding to the nearest times in the PET. The urea D/P ratio at 180 min and the creatinine D/P ratio at 240 min of the PET were the parameters that better estimated nocturnal clearances on APD. CONCLUSIONS This study confirms that TPD does not improve the results of CCPD. Significant differences between D/P ratios during actual nocturnal cycles and PETs were observed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Developing a Device for Automated Peritoneal Dialysis

Background: Peritoneal dialysis (PD) is an efficient alternative for hemodialysis. Removal of waste metabolites and excess water from the blood circulation are the two main tasks done during dialysis. These are done by using a filter; in PD, the naturally semi-permeable peritoneal membrane acts as the filter. Automated PD machines control intelligently the operations to enhance the efficiency a...

متن کامل

Effectiveness of Automated Peritoneal Dialysis Compared to Outpatient Procedure: A Systematic Review and Meta-analysis Study

Introduction: The growing trend of renal failure has focused clinical therapy on the cost-effective alternatives such as peritoneal dialysis. Therefore, the present study has investigated the effectiveness of two methods of continuous and automatic peritoneal dialysis in the patients with end stage renal disease. Methods: This study was conducted in the form of a systematic review. Advanced se...

متن کامل

Normalization of haemoglobin: why not?

It has been suggested that normalization of haemoglobin with epoetin in anaemic chronic renal failure (CRF) patients might result in even greater benefits than those currently achieved with partial haemoglobin correction. Four prospective randomized trials recently examined this hypothesis. The Scandinavian Multicentre Trial, which was completed in February 1998, included 416 haemodialysis, con...

متن کامل

ANCA-associated vasculitis and anti-GBM disease: the experience in China.

during CAPD measured with intraperitoneal dextran 70. ASAIO Trans 1991; 37: 662–667 34. Van Biesen W, Carlsson O, Bergia R et al. Personal dialysis capacity (PDC(TM)) test: a multicentre clinical study. Nephrol Dial Transplant 2003; 18: 788–796 35. Van Biesen W, Van der Tol A, Veys N et al. The personal dialysis capacity test is superior to the peritoneal equilibration test to discriminate infl...

متن کامل

The role of automated peritoneal dialysis (APD) in an integrated dialysis programme.

While there is no doubt that renal transplantation would be the preferred option for all patients suffering from end stage renal disease, this is sadly an unrealistic aim for many patients in the UK. There is a shortage of donor organs and, with the increasing percentage of elderly patients on dialysis, under 50% of all dialysis patients are on the national transplant waiting list. Of the 12,00...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 13 9  شماره 

صفحات  -

تاریخ انتشار 1998