Comparing the Vertical Misfit of Casts Produced By Two Verification Jigs
نویسندگان
چکیده
COMPARING THEVERTICAL MISFIT OF CASTS PRODUCED BY TWO VERFICATION JIGS Abdulaziz Alqahtani, B.D.S. Marquette University, 2014 Purpose: To compare the dimensional accuracy between master casts fabricated with verification jigs made of acrylic resin and light cure Triad. Materials and Methods: 10 GC Pattern resin Pattern verifications jigs and 10 Triad gel verification jigs fabricated of a master cast of a mandibular model of 4 internal hex implants. A stone base was fabricated for each verification jig. One screw test was used to evaluate the vertical gap at the terminal abutment using a digital micrometer with an accuracy of 1μm to record the vertical gap for each sample. Results: Triad Gel group has the lowest average distortion value which is 27.8 μm and GC Pattern Resin group has an average value of 29.71 μm. There was no statistical significance difference between the two groups (p=.42) Conclusions: The Triad gel jigs did not produce superior fit compared to GC Pattern resin pattern in a master cast with four implants and with an internal connection.
منابع مشابه
Accuracy of implant casts generated with splinted and non-splinted impression techniques for edentulous patients: an optical scanning study.
BACKGROUND The accuracy of implant casts generated with various impression techniques was mainly investigated in vitro resulting in limited clinical data. PURPOSE (1) To compare the three-dimensional (3-D) accuracy of splinted and non-splinted impression techniques to the control casts (verification jigs) that had been used for actual patient treatment; and (2) to determine the maximum level ...
متن کاملEvaluation of a two-step pouring technique for implant-supported prostheses impression.
The aim of this study was to evaluate the efficacy of a pouring technique for implant-supported prostheses impressions. A metallic matrix (control group) with two implants positioned at 90 and 65 degrees was fabricated. The matrix was submitted to the direct transfer impression technique. In group CP (conventional pouring - n = 10), casts were obtained by the conventional pouring technique. In ...
متن کاملEffect of splinted and nonsplinted impression techniques on the accuracy of fit of fixed implant prostheses in edentulous patients: a comparative study.
PURPOSE The effect of different implant impression techniques on the accuracy of casts has been investigated mostly in vitro, and clinically relevant evidence is scarce. The purpose of this study was to investigate the effect of implant impression techniques--specifically, splinted versus nonsplinted--on the accuracy of fit of fixed implant prostheses in edentulous patients. MATERIALS AND MET...
متن کاملمقایسه تشخیص رادیوگرافیک عدم تطابق اباتمنتهای زیرکونیایی و تیتانیومی در سه نوع مختلف ناحیه اتصال
Background and Aims: In response to esthetic demand and use of zirconia abutments; detection of implant-abutment connection misfit is so important. The purpose of this study was to evaluate the sensitivity and specificity of radiographic images in the detection of abutment-implant connection misfit in zirconia and titanium abutments of three different implant connections. Materials and Met...
متن کاملDetermination of Incisal Point as Anterior Guide to Transfer Maxillary Casts to Articulator: A Pilot Study
Objectives Despite the importance to use face-bow record for transferring maxillary cast to articulator some dentists use average points to avoid the time taken and ease of use. The location of incisal point could help to set the maxillary cast or denture in an appropriate position in mounting stage. This study was designed to determine the incisal point location in ante...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2016