Radiation exposure to the child during cardiac catheterization.

نویسندگان

  • J D Waldman
  • P S Rummerfield
  • E A Gilpin
  • S E Kirkpatrick
چکیده

Few data are available regarding radiation exposure to children during cardiac catheterization. Using lithium fluoride thermoluminescent dosimeters, radiation exposure was measured during precatheterization chest roentgenography, fluoroscopy (hemodynamic assessment phase of catheterization) and cineangiography in 30 infants and children, ages 3 days to 21 years. Dosimeters were placed over the eyes, thyroid, anterior chest, posterior chest, anterior abdomen, posterior abdomen and gonads. Average absorbed chest doses were 24.5 mR during chest roentgenography, 5810 mR during catheterization fluoroscopy and 1592 mR during cineangiography. During the complete catheterization, average doses were 26 mR to the eyes, 431 mR to the thyroid area, 150 mR to the abdomen and 11 mR to the gonads. Radiation exposure during pediatric cardiac catheterization is low to the eyes and gonads but high to the chest and thyroid area. To decrease radiation dosage we suggest (1) low pulse-rate fluoroscopy; (2) substitution of contrast echocardiography for cineangiography; (3) large-plate abdominal/gonadal shielding; (4) a selective shield for thyroid area; (5) a very small field during catheter manipulation. Minimum radiation consistent with accurate diagnosis is optimal; however, erroneous or incomplete diagnosis is more dangerous than radiation-related hazards.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Radiation Exposure Pattern and Radiation Absorbed Dose Resulting from Occupational Exposure of Anesthesiologists to Ionizing Radiation

Introduction: Little information is available concerning the radiation exposure of anesthesiologists, and no such data have previously been collected in Iran. This prospective study was performed to determine the amount of radiation exposure of anesthesiologists for the purpose of assessing whether or not dangerous levels of radiation exposures were being reached, and to identify factors that c...

متن کامل

Risk of cancer associated with cardiac catheterization procedures during childhood: a cohort study in France

BACKGROUND Radiation can be used effectively for diagnosis and medical treatment, but it can also cause cancers later on. Children with congenital heart disease frequently undergo cardiac catheterization procedures for diagnostic or treatment purposes. Despite the clear clinical benefit to the patient, the complexity of these procedures may result in high cumulative radiation exposure. Given ch...

متن کامل

Radiation Dose Reduction during Radial Cardiac Catheterization: Evaluation of a Dedicated Radial Angiography Absorption Shielding Drape

Objectives. Radiation scatter protection shield drapes have been designed with the goal of decreasing radiation dose to the operators during transfemoral catheterization. We sought to investigate the impact on operator radiation exposure of various shielding drapes specifically designed for the radial approach. Background. Radial access for cardiac catheterization has increased due to improved ...

متن کامل

Effect of a real-time radiation monitoring device on operator radiation exposure during cardiac catheterization: the radiation reduction during cardiac catheterization using real-time monitoring study.

BACKGROUND The Radiation Reduction During Cardiac Catheterization Using Real-Time Monitoring study sought to examine the effect of a radiation detection device that provides real-time operator dose reporting through auditory feedback (Bleeper Sv; Vertec Scientific Ltd; Berkshire, UK) on patient dose and operator exposure during cardiac catheterization. METHODS AND RESULTS Between January 2012...

متن کامل

Research on reducing radiation exposure during cardiac angiography

Background/Purpose Recent advances in devices involving cardiac catheterization, especially interventional procedures, has lead to increase in examination time and consequent increase in fluoroscopy time and number of filming exposures. Increase in radiation exposure to the patients and the medical personnel has been closed up as a serious agenda. In this study, we focused on the factors that l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 64 1  شماره 

صفحات  -

تاریخ انتشار 1981