Preliminary assessment of interand intraobserver reproducibility, and normative values of renal mean transit time (MTT) and parenchymal transit time (PTT) for 99mTc-etylenodicysteine.

نویسندگان

  • Paweł Cichocki
  • Marian Surma
  • Wojciech Woźnicki
  • Małgorzata Bieńkiewicz
  • Anna Płachcińska
  • Jacek Kuśmierek
چکیده

BACKGROUND The clinical significance of MTT and PTT, determined by deconvolution of renographic curves, is arguable. Their usefulness in diagnosis of obstructive uro- and nephropathy, renovascular hypertension and monitoring of transplanted kidneys is pointed out, but susceptibility of deconvolution methods to errors resulting from "statistical noise" is also stressed. So far there are no reports on normative MTT values for 99mTc-EC, although such values were already determined for ¹³¹I-OIH, 99mTc-DTPA and 99mTc-MAG3. The aim of this study is an assessment of inter- and intraobserver reproducibility of MTT and PTT for 99mTc-EC, and determination of normative values for these parameters. MATERIALS AND METHODS 31 patients (17 women and 14 men aged 19-75, average 44 years) referred for dynamic renal scintigraphy with: unilateral flow impairment (11), unilateral nephrolithiasis (2), control after unilateral lithotripsy (4), moderate hypertension (demographically with > 99% probability of primary hypertension) (4), suspected cirrhosis of one kidney (3), future kidney donors (3), control after abdominal injuries (3), incontinence (1). 42 functionally efficient kidneys were included in the study. Criteria for recognition of a kidney as functionally efficient were: - no earlier history of renal disease, signs of renal damage in basic blood and urine tests, or abnormalities in ultrasonography; - normal result of dynamic renal scintigraphy (in terms of sequential images and renographic curve). MTT and PTT values were determined independently by two operators, using a matrix method for deconvolution of renographic curves. RESULTS Differences between mean MTT and PTT from two studies by one operator were insignificant and those values were closely correlated (r = 0.99 and r = 0.97, respectively). Differences of values obtained by both operators were practically insignificant for MTT (r = 0.93), and significant for PTT (r = 0.81 and p < 0.001). These differences do not disqualify that processing method. The upper limits of normative values of MTT and PTT were based on the results from first study performed by more experienced operator - 200 s and 170 s, respectively. CONCLUSIONS The procedure of processing dynamic renal scintigraphy used in this study is reproducible. Normative values of MTT and PTT for 99mTc-EC were established as 200 s and 170 s, respectively. An attempt to optimize and standardize the technique of determining parenchymal ROI in a matrix deconvolution method, followed by an evaluation of clinical usefulness of these parameters in the diagnosis of chosen renal function impairments would be a logical continuation of this initial research.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calculation of 99mTc-DTPA transit times in normal kidney [Persian]

Introduction: Renal dynamic study is a well-established and popular test in routine practice of nuclear medicine. The test is non-invasive, rapid and unique in evaluation of the kidney function. In despite of its clinical values, the parameters derived from renogram are physiologically meaningless. That is due to the fact that renogram is not the true kidney function. From mathematical po...

متن کامل

Assessment of deconvolution technique for diagnosis of hydronephrosis in infants (under 6 months) [persian]

Introduction: Hydronephrosis is one of the major causes of referring infants for nuclear medicine investigation. Renal dynamic study is the most reliable investigation for such children. However direct evaluation of renogram leads to generation of parameters that have no physiological interpretation. The configuration of renogram is very much dependent upon the rate at which radiopharmace...

متن کامل

Parenchymal mean transit time analysis of 99mTc-DTPA captopril renography.

UNLABELLED Proposed renal hemodynamic mechanisms of captopril suggest that quantitation of renographic retention parameters should help identify patients suspected of having renovascular disease. The parenchymal mean transit time (MTT) is theoretically superior to other measures of retention, but data supporting its superiority are few. METHODS Two groups of subjects were studied with diethyl...

متن کامل

Reliability, repeatability, and reproducibility of pulmonary transit time assessment by contrast enhanced echocardiography

BACKGROUND The aim of this study is to investigate the inter and intra-rater reliability, repeatability, and reproducibility of pulmonary transit time (PTT) measurement in patients using contrast enhanced ultrasound (CEUS), as an indirect measure of preload and left ventricular function. METHODS Mean transit times (MTT) were measured by drawing a region of interest (ROI) in right and left car...

متن کامل

Independent assessment of source transit time for the BEBIG SagiNova® high dose rate brachytherapy afterloader

Introduction: The dwell time and transit time components contribute to the overall delivered dose to patients in high dose rate (HDR) brachytherapy treatments. The transit time results from source entry and exit as well as source movements between dwell positions. It depends on various parameters such as the source speed profile, source indexer distance to dwell position, and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nuclear medicine review. Central & Eastern Europe

دوره 18 1  شماره 

صفحات  -

تاریخ انتشار 2015