Effects of Intracorneal Ring Segment on Corneal Biomechanics in Keratoconic Eyes

نویسنده

  • Javad Amoozadeh
چکیده

Purpose: To evaluate the biomechanical changes of cornea after intracorneal ring segment (ICRS) implantation in keratoconic eyes Methods: In this study, 1 or 2 ICRS were inserted in 17 keratoconic eyes. Best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity (UCVA), refraction, and keratometry were evaluated preoperatively and 1 and 3 months after surgery. Corneal hysteresis (CH) and corneal resistance factor (CRF) were also measured preoperatively and postoperatively with ocular response analyzer (ORA). Results: ICRS was inserted in 17 keratoconic eyes (12 patients). Mean UCVA significantly increased from 0.72±0.37 logMAR to 0.54±0.27 logMAR (P=0.027) and 0.46±0.30 logMAR (P=0.01) 1 and 3 months after surgery, respectively. Mean BSCVA increased from 0.41±0.29 logMAR to 0.32± 0.26 logMAR at the end of the 1 month and 0.32±0.27 logMAR at the end of 3 month postoperatively. These changes were not significant. Spherical equivalent (SE) significantly decreased from -5.64±3.21 Diopter (D) to -3.36±2.74 D (P=0.009) 1 month and -3.51±2.04 D (P=0.002) at the 3 months after surgery. Mean keratometry also significantly decreased from 49.82±4.33 D to 48.10±3.64 D (P=0.010) and 47.40±3.47 D (P=0.003) at 1and 3month follow-ups, respectively. Mean CH was 7.48±1.65 mmHg and mean CRF was 5.98±2.06 mmHg, preoperatively. At 1-month follow-up, their values were 7.13±1.56 mmHg and 5.74±1.60 mmHg, respectively. At 3-month follow-up, their values were 7.20±1.23 mmHg and 5.80±1.72 mmHg, respectively. The CH and CRF changes at 1and 3-month follow-ups were not significant. Conclusion: After ICRS insertion in keratoconic eyes, no significant changes were observed in mean values measured with the ORA at 1and 3-month follow-ups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling the intracorneal ring segment effect in keratoconus using refractive, keratometric, and corneal aberrometric data.

PURPOSE To characterize the refractive, keratometric, and corneal aberrometric effect of a specific type of intracorneal ring segment (ICRS) as a function of its thickness and the preoperative conditions of the cornea. METHODS A total of 72 consecutive keratoconic eyes of 57 patients ranging in age from 15 to 68 years were retrospectively analyzed and included in the study. All cases had a di...

متن کامل

Complications of intrastromal corneal ring segment implantation using a femtosecond laser for channel creation: a survey of 850 eyes with keratoconus.

PURPOSE To report complications after the implantation of intrastromal corneal ring segments (Keraring; Mediphacos, Belo Horizonte, Brazil) in keratoconic eyes using a femtosecond laser (IntraLase; Advanced Medical Optics, Santa Ana, California, USA) for channel creation. METHODS Retrospective chart review of 531 patients (850 eyes) who underwent Keraring insertion using a femtosecond laser f...

متن کامل

Ferrara intracorneal ring segments for keratoconus.

PURPOSE To assess the outcome of Ferrara intracorneal ring segments for keratoconus. SETTING Private practice and university hospital, Porto Alegre, Brazil. METHODS In this retrospective noncomparative interventional case series, 51 keratoconus eyes of 47 patients that had Ferrara intracorneal ring segment implantation were reviewed. Uncorrected visual acuity (UCVA), best spectacle-correcte...

متن کامل

Quantitative OCT-based corneal topography in keratoconus with intracorneal ring segments

Custom high-resolution high-speed anterior segment spectral domain Optical Coherence Tomography (OCT) was used to characterize three-dimensionally (3-D) corneal topography in keratoconus before and after implantation of intracorneal ring segments (ICRS). Previously described acquisition protocols were followed to minimize the impact of the motions of the eye. The collected set of images was cor...

متن کامل

Quantitative OCT-based longitudinal evaluation of intracorneal ring segment implantation in keratoconus.

PURPOSE To characterize the geometrical properties of keratoconic corneas upon intracorneal ring segments (ICRS) implantation, using custom-developed optical coherence tomography (OCT). METHODS Ten keratoconic corneas were measured pre- and post-ICRS surgery (7, 30, and 90 days). Corneal topographic and pachymetric maps were obtained from three-dimensional (3D) images acquired with OCT, provi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010