Efficacy of antimicrobial polymer coatings in an animal model of bacterial infection associated with foreign body implants.

نویسندگان

  • Emily Hart
  • Kristy Azzopardi
  • Heng Taing
  • Florian Graichen
  • Justine Jeffery
  • Roshan Mayadunne
  • Malsha Wickramaratna
  • Mike O'Shea
  • Brunda Nijagal
  • Rebecca Watkinson
  • Stephen O'Leary
  • Barrie Finnin
  • Russell Tait
  • Roy Robins-Browne
چکیده

OBJECTIVES To assess support discs, comprising polyethylene terephthalate (PET), coated with different polymer/levofloxacin combinations for antimicrobial activity in an animal model of infection, in order to explore the use of specific polymer coatings incorporating levofloxacin as a means of reducing device-related infections. METHODS Aliphatic polyester-polyurethanes containing different ratios of poly(lactic acid) diol and poly(caprolactone) diol were prepared, blended with levofloxacin and then used to coat support discs. The in vitro levofloxacin release profiles from these discs were measured in aqueous solution. Mice were surgically implanted with the coated discs placed subcutaneously and infection was initiated by injection of 10(6) cfu of Staphylococcus aureus into the subcutaneous pocket containing the implant. After 5, 10, 20 and 30 days, the discs were removed, and the number of bacteria adhering to the implant and the residual antimicrobial activity of the discs were determined. RESULTS In vitro, the release of levofloxacin from the coated discs occurred at a constant rate and then reached a plateau at different timepoints, depending on the polymer preparation used. In vivo, none of the discs coated with polymer blends containing levofloxacin was colonized by S. aureus, whereas 94% of the discs coated with polymer alone were infected. All discs coated with levofloxacin-blended polymers displayed residual antimicrobial activity for at least 20 days post-implantation. CONCLUSIONS Bioerodable polyester-polyurethane polymer coatings containing levofloxacin can prevent bacterial colonization of implants in an intra-operative model of device-related infections.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Foreign Body Infection Models to Study Host-Pathogen Response and Antimicrobial Tolerance of Bacterial Biofilm.

The number of implanted medical devices is steadily increasing and has become an effective intervention improving life quality, but still carries the risk of infection. These infections are mainly caused by biofilm-forming staphylococci that are difficult to treat due to the decreased susceptibility to both antibiotics and host defense mechanisms. To understand the particular pathogenesis and t...

متن کامل

Toward Infection-Resistant Surfaces: Achieving High Antimicrobial Peptide Potency by Modulating the Functionality of Polymer Brush and Peptide.

Bacterial infection associated with indwelling medical devices and implants is a major clinical issue, and the prevention or treatment of such infections is challenging. Antimicrobial coatings offer a significant step toward addressing this important clinical problem. Antimicrobial coatings based on tethered antimicrobial peptides (AMPs) on hydrophilic polymer brushes have been shown to be one ...

متن کامل

Implants modified with polymeric nanofibers coating containing the antibiotic vancomycin

Objective(S): Implant-related infections are disastrous complications in the clinic. One recent strategy to reduce the rate of infection is using the bioactive coating with an antibiotic. The purpose of these bioactive surfaces is to prevent bacterial adhesion to the implant and, consequently, the development of biofilm. In this study, vancomycin-loaded polymeric coating on imp...

متن کامل

Gentamicin-loaded bioresorbable films for prevention of bacterial infections associated with orthopedic implants.

Adhesion of bacteria to biomaterials and the ability of many microorganisms to form biofilms on foreign bodies are well-established as major contributors to the pathogenesis of implant-associated infections. Treatment of bone infection remains problematic, due to the difficulty of systemically administered antibiotics to locally penetrate bone. The current research addresses this issue by focus...

متن کامل

Antimicrobial, biocompatible surface coatings for a permanent transcutaneous passage in the concept of osseointegrated limb prosthesis

INTRODUCTION: Osseointegration of amputation limb prosthesis appears to be a promising approach to improve quality of life and mobility of amputees in comparison to conventional socket attached devices. However, the clinical implementation of those bone anchored transcutaneous systems is still limited due to infections at the side of the percutaneous passage. In theory a stable adherence of the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of antimicrobial chemotherapy

دوره 65 5  شماره 

صفحات  -

تاریخ انتشار 2010