High Defibrillation Threshold: The Science, Signs and Solutions

نویسندگان

  • Sony Jacob
  • Victorio Pidlaoan
  • Jaspreet Singh
  • Aditya Bharadwaj
  • Mehul B Patel
  • Antonio Carrillo
چکیده

Defibrillation threshold (DFT) testing has traditionally been an integral part of implantable cardioverter defibrillator (ICD) implantation. With the increasing number of patients receiving ICDs, physicians are encountering high DFT more often than before. Tackling the problem of high DFT, warrants an in-depth understanding of the science of defibrillation including the key electrophysiological concepts and the underlying molecular mechanisms. Numerous factors have been implicated in the causation of high DFT. Due consideration to the past medical history, pharmacotherapy, laboratory data and cardiac imaging, help in assessing the pre-procedural risk for occurrence of high DFT. Drugs, procedural changes, type and location of ICD lead system are some of the key players in predicting DFT during implantation. In the event of encountering an unacceptably high DFT, we recommend to follow a step-wise algorithm. Ruling out procedural complications like pneumothorax and tamponade is imperative before embarking on a search for potentially reversible clinical or metabolic derangements. Finally, if these attempts fail, the electrophysiologist must choose from a wide range of options for device adjustment and system modification. Although this review article is meant to be a treatise on the science, signs and solutions for high DFT, it is bound by limitations of space and scope of the article.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Solution for the High Defibrillation Threshold in Patients with a DF-4 Lead: Adding a High Voltage Adaptor/Splitter

A high defibrillation threshold occurs in approximately 6% of implants. The defibrillation threshold can be improved by addition of a defibrillation lead. However, the DF-4 high energy ICD header precludes the addition of a defibrillation lead. Here we report on use of a new high voltage adaptor/splitter that enables the addition of an extra defibrillation lead.

متن کامل

Director Structures in a Chiral Nematic Slab: Threshold Field and Pitch Variations

Abstract The liquid crystal director distribution is determined for a confined chiral nematic slab. The molecular director distribution of the field-controlled chiral nematic slab is directly calculated. The director profiles for the tilt and the twist angles, under different applied fields, are calculated in the slab with weak boundary conditions. Then, the dependence of the threshold field on...

متن کامل

Azygos Vein Lead Implantation For High Defibrillation Thresholds In Implantable Cardioverter Defibrillator Placement

Evaluation of defibrillation threshold is a standard of care during implantation of implantable cardioverter defibrillator. High defibrillation thresholds are often encountered and pose a challenge to electrophysiologists to improve the defibrillation threshold. We describe a case series where defibrillation thresholds were improved after implanting a defibrillation lead in the azygos vein.

متن کامل

Pre-discharge defibrillation testing: Is it still justified?

BACKGROUND An implantable cardioverter-defibrillator (ICD) is routinely used to prevent sudden cardiac death. Since the introduction of that device into clinical practice, a defibrillation test (the so-called pre-discharge test [PDT]) has been an inseparable part of the ICD implantation procedure. Recently, the usefulness of PDT has been called into question. METHODS The aim of this research ...

متن کامل

Clinical Characteristics and Outcome of Patients With High Defibrillation Thresholds

Background. Successful defibrillation by an implantable cardioverter-defibrillator (ICD) depends on its ability to deliver shocks that exceed the defibrillation threshold. This study was designed to identify clinical characteristics that may predict the finding of an elevated defibrillation threshold and to describe the outcome of patients with high defibrillation thresholds. Methods and Result...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2010