Should a fixed external reference system be used to analyze left ventricular wall motion?

نویسندگان

  • P D Clayton
  • G M Jeppson
  • S C Klausner
چکیده

To investigate whether a fixed external reference system should be used to most accurately describe regional left ventricular wall motion, we used vectors to analyze a simple model of ventricular contraction. If measured in a fixed external reference system, motion of implanted radiopaque midwall markers may contain translational as well as contractile components. Therefore, comparisons of different reference systems that use marker motion measured in a fixed reference system as a standard will be biased unless proper corrections are included. We conclude that evidence to data does not indicate that the use of a fixed reference system is superior to other methods for analyzing regional ventricular wall motion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of methods for quantitating left ventricular segmental wall motion in man using myocardial markers as a standard.

Radiopaque markers were implanted in the left ventricular myocardial midwall in 58 patients and studied in the 30 degrees right anterior oblique projection by computer-aided fluoroscopy. Marker motion was used as a standard of segmental wall motion against which the accuracy of five methods for measuring left ventricular wall motion was assessed: two methods using hemiaxial measurements in rect...

متن کامل

Quantitative two-dimensional echocardiographic analysis of motion and thickening of the interventricular septum after cardiac surgery.

Septal and lateral wall motion and septal thickening were evaluated with quantitative two-dimensional echocardiography in 20 patients who underwent cardiac surgery without complications. Postoperative mean ejection fraction (48 +/- 10%) measured by radionuclide ventriculography was unchanged from the preoperative value (45 +/- 8%). Mean postoperative systolic thickening of the septum (33 +/- 15...

متن کامل

DIAGNOSTIC METHODS PERIOPERATIVE MYOCARDIAL INFARCTION Quantative two-dimensional echocardiographic analysis of regional wall motion in patients with perioperative myocardial infarction

Regional left ventricular wall motion was evaluated by two-dimensional echocardiographic techniques with fixedand floating-axis analytical algorithms in three groups of subjects: normal subjects (n = 15), patients undergoing uncomplicated coronary artery bypass graft surgery (CABG) (n = 10), and patients suffering perioperative myocardial infarction (n 27). In patients undergoing uncomplicated ...

متن کامل

Evaluation of Methods for Quantitating Left Ventricular Segmental Wall Motion in Man

Radiopaque markers were implanted in the left ventricular myocardial midwall in 58 patients and studied in the 30° right anterior oblique projection by computer-aided fluoroscopy. Marker motion was used as a standard of segmental wall motion against which the accuracy of five methods for measuring left ventricular wall motion was assessed: two methods using hemiaxial measurements in rectangular...

متن کامل

Evaluation of Methods for Quantitating Left Ventricular Segmental Wall Motion in Man Using Myocardial Markers

Radiopaque markers were implanted in the left ventricular myocardial midwall in 58 patients and studied in the 30° right anterior oblique projection by computer-aided fluoroscopy. Marker motion was used as a standard of segmental wall motion against which the accuracy of five methods for measuring left ventricular wall motion was assessed: two methods using hemiaxial measurements in rectangular...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 65 7  شماره 

صفحات  -

تاریخ انتشار 1982